Maguire Products, Inc.
Rev. December 18, 2019
– ULTRA-1000 Touchscreen
53
ULTRA By Maguire
- Ultra Low Energy Dryer
DPD - Dry Purge Delay
[ULTRA-600 and ULTRA-1000 only]
format:
xxyyy (seconds / seconds)
function(s):
xx:
The amount of time between the purge air solenoid valve opening and the
purge air heater powering-up
yyy:
The amount of time between the purge air heater powering-down and the purge
air solenoid valve closing.
PST - Purge and Shutdown Time
[ULTRA-600 and ULTRA-1000 only]
format:
xxxxx (minutes)
function(s):
The amount of time that the purge air system will continue to run after the final vacuum
chamber dispense.
H2W - Purge Heater Wattage
[ULTRA-600 and ULTRA-1000 only]
format:
xxxxx (watts)
function(s):
Wattage of the purge heater. This value is used in energy consumption calculations.
Load Cell
KDF -Load Cell Stable Weight
format:
xxxxx (counts)
function(s):
Maximum allowable load cell fluctuations during a weight reading during filling
operations. A lower number will equate to a more accurate reading but could slow the
system down.
LST -Load Cell Stable Time
format:
xxxxx (milliseconds)
function(s):
The amount of time that the load cell raw counts must remain within the window
established by KDF before a weight reading is taken.
LCZ -Load Cell Zero
format:
xxxxx (counts)
function(s):
Maximum allowable load cell fluctuations during a weight reading during zero and full
calibration.