background image

Whole Room Dryer  

WRD, WRD/110

User Instructions 

Whole Room Dryers

12/06

CAUTION - READ THESE INSTRUCTIONS BEFORE USING THE MACHINE

03-8117-0000 Iss.1 

 

 

 

 

 

Summary of Contents for WRD

Page 1: ...Whole Room Dryer WRD WRD 110 User Instructions Whole Room Dryers 12 06 CAUTION READ THESE INSTRUCTIONS BEFORE USING THE MACHINE 03 8117 0000 Iss 1 ...

Page 2: ...Fig 1 Fig 2 Fig 4 Fig 3 ...

Page 3: ...r the operator 4 1 3 Transporting the machine 4 2 Preparing for use 5 2 1 Electrical connection 5 3 Controls 5 4 Operation 5 5 Storage 5 6 Maintenance 5 7 After sales service 5 8 Guarantee 5 9 Technical specification 6 10 Fault diagnosis 6 11 Declaration of conformity 7 CONTENTS ...

Page 4: ... Do not use where hazardous dust is present Do not use near flammable fluids dusts or vapours Do not use in an explosive atmosphere Take care when using a machine near the top of stairs to avoid overbalancing Warning do not stack dryers more than two units high without tie downs 1 2 Guidelines for the operator Operators must be fully trained in the use of the machine in accordance with these instr...

Page 5: ...rised technicians It is always apparent that after longer working periods elec trical and mechanical components will show signs of wear and tear or ageing To maintain operational safety and reliability the following service interval has been defined Every year or after 250 hours Under extreme or specialised conditions and or insuffi cient maintenance shorter maintenance intervals are necessary Use...

Page 6: ...ze h x w x l cm 61x58x66 61x58x66 Weight kg 24 24 Warranty years 1 1 1 Noise levels measured at a distance of 1 metre from machine and 1 6 metres above floor Measurements recorded using a hand held meter The following simple checks may be performed by the operator If the fuse blows several times the machine should be checked by an authorised Service Agent 10 Fault diagnosis Trouble Reason Remedy M...

Page 7: ...ing transposed harmonised European Standards and technical specifications BS EN 50081 1 BS EN 55014 1 2 BS EN 60335 1 and BS EN 60335 2 67 and is in conformity with the Machinery Directive 89 392 EEC and subsequent amendments the Low Voltage Directive 73 23 EEC and subsequent amendments and the EMC Directive 89 336 EEC and subsequent amendments Signed in SOUTHAMPTON England on the 1st day of Decem...

Page 8: ...Truvox International Limited Third Avenue Millbrook Southampton Hampshire SO15 0LE England Tel 44 0 23 8070 2200 Fax 44 0 23 8070 5001 e mail truvox truvox com Web www truvox com ...