8 Troubleshooting
8.1 General Troubleshooting
Problem
Error on Display
Cause
Transmitter shuts down during
normal operation
Off Activated
Unit has been turned off by the operator.
Machine Stop
Machine stop has been pressed by the
operator.
Inactivity Timeout
No input has been activated on the
transmitter for the period of time set for
the inactivity timer.
Low Battery
Transmitter battery is too low.
Drop Detected
A drop of the transmitter has been
detected where it has struck an object.
Long Drop Detected
A freefall drop of the transmitter has been
detected.
TILT
Tilt detection in the transmitter is enabled
and the angle of the tilt is beyond the
acceptable range.
Key Switch Power Off
The transmitter key switch input has
been turned off.
Transmitter shuts down during
initialization
On/Off Switch FAIL
An error has been detected with the Off/
On/Start switch during startup. Check the
connection between the switch and the
board.
Estop FAIL
An error has been detected with the E-
stop switch during startup. Check the
connection between the switch and the
board.
Motion X failed
An error has been detected with Motion X
during startup where it is not centered.
Return Motion X to the center position
and cycle power to the transmitter. Refer
to the system drawings to determine the
location of the switch.
Motion X dir failed
An error has been detected with Motion X
during startup. Check the connection
between the input and the board. Refer
to the system drawings to determine the
location of the switch.