![background image](http://html1.mh-extra.com/html/magnetek/chtx/chtx_instruction-manual_3584902027.webp)
Enrange CHTX Transmitter Instruction Manual
December 2017
Page 27 of 47
The dip switch settings will take effect upon the next power cycle of the transmitter.
NOTE:
If using the optional RCP software on transmitters NOT equipped with the
graphic user interface, the channel settings will read from the dip switch positions and
not from memory when the channel from memory override function is not enabled. The
RF channel set by the optional RCP software will not be used unless the memory
override dip switch is set to ON. When the RF channel from memory override is NOT
enabled, the dip switch positions set the RF channel used by the transmitter.
NOTE:
The transmitters equipped with the optional graphic user interface will read
channel settings from memory and will not respond to dip switch changes for the
channel setup. Only the dip switches for the battery life indication are functional on
graphic user interface equipped transmitters.
4.2 Using the Transmitter in Setup Mode (with Optional
Graphic User Interface)
NOTE:
The Setup Mode is only accessible on transmitters equipped with the optional graphic
user interface. The units equipped with the standard status LED can have the settings of the
transmitter changed at the factory.
The Setup Mode can be used to edit configuration settings such as Access Code, Channel Select, User
Code, Transmitter Time Out, Backlight Time Out, Password Enable, and Change Password.
NOTE:
No parameter changes will take effect until the user has selected ‘Save and Exit’ from
the Setup Mode.
4.2.1
Entering Setup Mode
To enter the Setup Mode, make sure the unit is off and the Machine Stop switch is
raised. Push the OFF/ON/START toggle switch to the START position, and hold it in the
START position for more than 5 seconds until the setup screen appears.
A prompt for a 4-digit password will appear if the password feature is enabled. If no
password is enabled, the adjustments in
Section 4.2.2 on page 27
will be available
with no further input required from the user.
NOTE:
The password feature is enabled by default from the factory.
Use the Joystick/Paddle to increment or decrement the value, and toggle to the START
position when finished. If the password is entered correctly, the device will enter Setup
Mode. If the password is entered incorrectly, the device will power down.
NOTE:
The factory default password to get into the setup menu is
0000
.
4.2.2
Adjusting Settings in Setup Mode
To navigate through Setup Mode, the Joystick/Paddle designated (MTN 1) and OFF/
ON/START switch are used. The Joystick/Paddle cycles through the menus and is also
used to change parameters within the menus. Pushing the OFF/ON/START switch to
the START position will toggle between the menu and its parameter(s). When adjusting
larger values, the speed is dependent on how far the Joystick/Paddle is depressed.
NOTE:
No parameter changes will take effect until the user has selected ‘Save and
Exit’ from the Setup Mode.