NOTE:
The dip switch block switches are oriented so that the OFF position is next to
the number designator and the ON position is up or away from the number designator.
Once the dip switch board has been set for the proper battery type, the CPU board must
be re-installed in the CHTX housing. Flip the CPU board over and secure it to the
support structure using the four Phillips head screws that originally held it in place.
Once the CPU board is secured, plug the ribbon back in, close the CHTX housing, and
secure the front and side clamps.
3.3 Turning the Transmitter On and Off
The CHTX uses both a three-position toggle switch labeled OFF/ON/START and a Machine Stop switch to
turn the transmitter on or off. There are two different methods to turn on the transmitter depending upon the
toggle that is used and how the software is configured:
•
The primary method to power on the transmitter uses OFF/ON/START toggle part number
198-80500-0005. With this toggle and software configuration, the unit is powered on by moving the
switch to the ON position.
•
The alternate method to power on the transmitter uses OFF/ON/START toggle part number
178-01600-0100. With this toggle and software configuration, the unit is powered on by moving the
switch to the START position and releasing it after 2 seconds.
NOTE:
The method to power on the unit relies on both the hardware and software configuration
matching. The software configuration for the powering of the unit can only be changed by the
factory. Contact the factory if a different power-on sequence is desired.
NOTE:
Refer to the system drawings to determine which toggle is installed. This will be an
indicator of which power-on sequence is used.
Fig. 10: Machine Stop Switch and OFF/ON/START Toggle