![Magnetek CHTX Instruction Manual Download Page 23](http://html1.mh-extra.com/html/magnetek/chtx/chtx_instruction-manual_3584902023.webp)
Enrange CHTX Transmitter Instruction Manual
December 2017
Page 23 of 47
3.8 Normal Operating Mode with Optional Graphic User
Interface
In normal operating mode, the CHTX displays real-time information relating to the operation of the
transmitter on the graphic user interface. Information may include Command Confirmation, Battery Life,
Signal Strength, Two-Way Feedback, etc.
Fig. 12: Normal Operating Screen on Graphic User Interface
3.8.1
Watchdog Indicator (Spinning Arrow)
The spinning arrow represents the watchdog timer within the CPU of the unit.
NOTE:
The arrow should be continuously spinning at all times. If the arrow is not
spinning, the transmitter must be rebooted to operate properly.
3.8.2
Command Confirmation
Each time the user operates a control on the transmitter, a message will be displayed
on the graphic user interface screen confirming what is being operated.
For example, if the second paddle is moved to its 4th position in the UP direction, the
display will show the following:
MTN2 D1 SP=4
This translates to ‘Motion 2, Direction 1, Speed 4’
3.8.3
Battery Life Indicator
Remaining battery life is displayed in the bottom left hand corner of the graphic user
interface screen.
Battery life is displayed in 5% increments.
NOTE:
If using an optional battery pack different from what the unit was shipped from
the factory with, the battery life indicator will be inaccurate unless the dip switch settings
are set to the correct battery type being used.
See Section 3.2.3 on page 16
for details
to properly set the dip switches.
NOTE:
The battery life indicator will only show accurate battery life when using
Magnetek-approved battery packs.