[Part 4] Technical Support
//84
www.madrix.com
MADRIX STELLA User Manual
STELLA Firmware
2.03.7291
MADRIX Version
MADRIX 5.4
Release Date
December 2020
§
Fixed minor issues.
STELLA Firmware
2.04.7304
MADRIX Version
MADRIX 5.4a
Release Date
February 2021
§
Web configuration page: Fixed an incorrect IP address shown for sACN Multicast
Mode (#6562).
§
Fixed a critical issue that could halt the device when receiving an Art-Net OpIpProg
request (#6852).
§
Fixed an issue that did not save the chosen value for the 'In Case Of Network Data
Timeout' setting for the second port (#6899).
§
Fixed an issue that did send back the On/Off state of RDM for Port 2 incorrectly in
the Art-Net PollReply (#6915).
STELLA Firmware
2.05.7308
MADRIX Version
MADRIX 5.4b
Release Date
May 2021
§
The device now replies with ArtTodData to an ArtTodControl request for improved
compatibility with Art-Net 4 (#6958).
§
Improved and streamlined how the device replies to ArtTodData with Unicast,
Directed Broadcast, or Limited Broadcast (#6959).
STELLA Firmware
2.06.7355
MADRIX Version
MADRIX 5.4c
Release Date
July 2021
§
Web configuration page: Added the option to set the Output Intensity (#7317).
§
Web configuration page: Added the option to set the Upper Intensity Limit (#7317).
§
Web configuration page: Added the option to reboot the device (#7403).
§
Web configuration page: Added the option to reset the device to factory default
settings (#7403).
§
Fixed an issue that could prevent changed settings from being saved in rare cases
after a power cycle (#5382).
§
Fixed an issue that did not show the favicon in web browsers (#6460).
§
Fixed that the option Send The Last Received Frame Continually did not work
correctly when a universe failed after having received two universes of data
(#7344).
STELLA Firmware
3.00.7380
MADRIX Version
MADRIX 5.4e
Release Date
October 2021
§
Updated the system of the device (#6971, #7114, #7504).
§
Updated the bootloader of the device (#7544).
§
A single bootloader now supports both Ethernet ports (#7695).
§
A maximum of 170 RDM Responders can now be discovered per port (#7479).
§
Improved the timing of RDM packets (#7479).
§
RDM packets are now also forwarded during a discovery of connected RDM
Responders (#6726).
§
All RDM packets that are not processed by the device itself are forwarded
unchanged to the RDM Controller (#7639).
§
Changes regarding connected RDM Responders are now also evaluated with the
help of the UID itself in addition to the UID count (#7683).
Summary of Contents for STELLA
Page 1: ...2022 inoage GmbH MADRIX STELLA User Manual Date March 2022 Hardware User Guide...
Page 3: ...1 PART Overview...
Page 11: ...2 PART Device Configuration...
Page 14: ...Part 2 Device Configuration 14 www madrix com MADRIX STELLA User Manual...
Page 21: ...3 PART Using MADRIX 5 Software...
Page 57: ...Part 3 Using MADRIX 5 Software 57 www madrix com MADRIX STELLA User Manual...
Page 80: ...4 PART Technical Support...
Page 86: ...5 PART General...
Page 102: ...Part 5 General 102 www madrix com MADRIX STELLA User Manual...
Page 103: ...Part 5 General 103 www madrix com MADRIX STELLA User Manual...
Page 106: ...Part 5 General 106 www madrix com MADRIX STELLA User Manual...
Page 112: ...6 PART Legal...