92
73VR2102 / 73VR2104 / 73VR2106 / 73VR2108 / 73VR2110 / 73VR2112 USERS MANUAL EM-7395-B Rev.24
10.4 HOT SWAPPING THE CF CARD
The CF Card can be replaced while the 73VR21x is running.
The data sampled while the card is not placed is stored in the 73VR21x’s internal memory. Its capacity is enough
approximately for 5 minutes without a card. Be sure to get ready with a CF Card for replacement. If the CF Card
does not contain the files 73VR.VRD21, 73VR.VRP21, 73VR.VRC21, 73VR.VRM21 and 73VR.VRA21, they must be
created beforehand using the 73VR21BLD Configurator software. If the CF Card already has these files with stored
data, they will be overwritten.
Be sure to observe the following procedure. If not, CF Card and its data may be damaged or lost.
HOW TO REPLACE THE CF CARD
(1) Call up the Menu on the Display view and touch CF Card Eject key.
(2) Confirm that you want to remove the CF Card. If not touch Cancel.
(3) Confirm that the Menu now shows CF Card Insert key, and extract the card.
NOTE
No data retrieval or alarm history display is available while the card is removed.
(4) Insert a new CF Card, and touch CF Card Insert key.
(5) The 73VR21x will ask you if you want to reset the data file if one exist. Confirm that and touch OK.
CAUTION !
The CF Card cannot be removed while data in the internal memory is transferred to the card, during the card replace-
ment or after the recording is complete. It may take certain time.
CAUTION !
The 73VRWV can perform FTP transfer while the 73VR21x is recording. The 73VR21x stores data in its internal
memory while the FTP is in progress. When the internal memory is full, the file transfer is stopped, and the 73VR21x
starts transferring data from the memory to the CF Card. Then with the transfer to the CF Card completed, the file
transfer to the 73VRWV is resumed. Due to this operating procedure, it usually takes longer time in a file transfer
when the 73VR21x is recording.
NOTE
Time elapsed (used file volume) since a card is removed can be confirmed on the Bargraph or the
Overview. The Data File Used Volume bargraph will indicated 100% after 5 minutes has been passed.
To use this function, choose Enable in the Display Setting.
NOTE
While the automatic comment entry is on, DO NOT execute a FTP data transfer.