Appendix D
© 2018 Avco Corporation. All Rights Reserved
Page 528
November 2018
TEO-540-C1A Engine Maintenance Manual
Fault ID
479
Fault Group
60
Fault Name
-Reserved-
Fault
Description
Fault Lamp
None
Root Cause
Troubleshooting Steps
Fault ID
480
Fault Group
61
Fault Name
[FAULT: ArithPU]
Fault
Description
Arithmetic processing unit fault
Fault Lamp
None
Root Cause
This fault indicates a fault with the arithmetic processor possibly due to a memory
corruption or processor failure
Fault ID
481
Fault Group
61
Fault Name
[FAULT: configurable value range
check failed]
Fault
Description
Configurable value range check failed
fault
Fault Lamp
None
Root Cause
This fault indicates one or more of the configurable values exceed their upper or lower
limits
Fault ID
482
Fault Group
61
Fault Name
[FAULT: Excessive Programming
Time]
Fault
Description
Excessive programming time fault
Fault Lamp
None
Root Cause
This fault indicates programming did not complete within the timeout limit
Troubleshooting Steps for Faults 480 thru 482
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault still active? If yes, replace ECU. If no, go to step 2.
2.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.
Fault ID
483
Fault Group
61
Fault Name
-Reserved-
Fault
Description
Fault Lamp
None
Root Cause
Troubleshooting Steps
Fault ID
484
Fault Group
61
Fault Name
-Reserved-
Fault
Description
Fault Lamp
None
Root Cause
Troubleshooting Steps