Appendix D
© 2018 Avco Corporation. All Rights Reserved
Page 536
November 2018
TEO-540-C1A Engine Maintenance Manual
Fault ID
552
Fault Group
70
Fault Name
[FAULT: CHT cyl 1 coss-check]
Fault
Description
CHT cyl 1 cross-check fault
Fault Lamp
FFL
Root Cause
This fault is a cross-check between local cylinder head temperature and inferred cylinder
head temperature has consistently exceeded its calibrated maximum threshold
Fault ID
553
Fault Group
70
Fault Name
[FAULT: CHT cyl 2 coss-check]
Fault
Description
CHT cyl 2 cross-check fault
Fault Lamp
FFL
Root Cause
This fault indicates a cross-check between local cylinder head temperature and inferred
cylinder head temperature has consistently exceeded its calibrated maximum threshold
Fault ID
554
Fault Group
70
Fault Name
[FAULT: CHT cyl 3 coss-check]
Fault
Description
CHT cyl 3 cross-check fault
Fault Lamp
FFL
Root Cause
This fault indicates cross-check between local cylinder head temperature and inferred
cylinder head temperature has consistently exceeded its calibrated maximum threshold
Fault ID
555
Fault Group
70
Fault Name
[FAULT: CHT cyl 4 coss-check]
Fault
Description
CHT cyl 4 cross-check fault
Fault Lamp
FFL
Root Cause
This fault indicates the cross-check of cylinder head temperature which means a cross-
check between local cylinder head temperature and inferred cylinder head temperature has
consistently exceeded its calibrated maximum threshold
Fault ID
556
Fault Group
70
Fault Name
[FAULT: CHT cyl 5 coss-check]
Fault
Description
CHT cyl 5 cross-check fault
Fault Lamp
FFL
Root Cause
This fault indicates the cross-check of cylinder head temperature which means a cross-
check between local cylinder head temperature and inferred cylinder head temperature has
consistently exceeded its calibrated maximum threshold
Fault ID
557
Fault Group
70
Fault Name
[FAULT: CHT cyl 6 coss-check]
Fault
Description
CHT cyl 6 cross-check fault
Fault Lamp
FFL
Root Cause
This fault indicates the cross-check of cylinder head temperature which means a cross-
check between local cylinder head temperature and inferred cylinder head temperature has
consistently exceeded its calibrated maximum threshold
Fault ID
558
Fault Group
70
Fault Name
[FAULT: CHT cyl 7 coss-check]
Fault
Description
CHT cyl 7 cross-check fault
Fault Lamp
FFL
Root Cause
This fault indicates the cross-check of cylinder head temperature which means a cross-
check between local cylinder head temperature and inferred cylinder head temperature has
consistently exceeded its calibrated maximum threshold
Fault ID
559
Fault Group
70
Fault Name
[FAULT: CHT cyl 8 coss-check]
Fault
Description
CHT cyl 8 cross-check fault
Fault Lamp
FFL
Root Cause
This fault indicates the cross-check of cylinder head temperature which means a cross-
check between local cylinder head temperature and inferred cylinder head temperature has
consistently exceeded its calibrated maximum threshold
Troubleshooting Steps for Faults 552 thru 559
1.
Run the engine in accordance with the engine and aircraft maintenance manuals. Is the fault active? *
If yes, go to step 3. If no, go to step 2.