![Lycoming TEO-540-C1A Maintenance Manual Download Page 535](http://html.mh-extra.com/html/lycoming/teo-540-c1a/teo-540-c1a_maintenance-manual_1953585535.webp)
© 2018 Avco Corporation. All Rights Reserved
Appendix D
November 2018
Page 505
TEO-540-C1A Engine Maintenance Manual
Fault ID
387
Fault Group
49
Fault Name
[FAULT: Timestamp Software
Calibration Version Discrepancy]
Fault
Description
Software calibration version timestamp
discrepancy fault
Fault Lamp
None
Root Cause
This fault indicates timestamp entry contains different application software version
potentially due to a memory corruption
Fault ID
388
Fault Group
49
Fault Name
[FAULT: Timestamp Software
Program Version Discrepancy]
Fault
Description
Software program version timestamp
discrepancy fault
Fault Lamp
None
Root Cause
This fault indicates timestamp entry contains different factory unit calibration version
potentially due to a memory corruption
Fault ID
389
Fault Group
49
Fault Name
[FAULT: Flash SPI Erase Fail]
Fault
Description
Flash SPI erase fail fault
Fault Lamp
None
Root Cause
This fault indicates a failure to erase the flash memory potentially due to flash memory
corruption.
Fault ID
390
Fault Group
49
Fault Name
[FAULT: Flash SPI read Fail]
Fault
Description
Flash SPI read fail fault
Fault Lamp
None
Root Cause
This fault indicates a failure to read the flash memory potentially due to flash memory
corruption.
Fault ID
391
Fault Group
49
Fault Name
[FAULT: Flash SPI write Fail]
Fault
Description
Flash SPI write fail fault
Fault Lamp
None
Root Cause
This fault indicates a failure to write to the flash memory potentially due to flash memory
corruption.
Troubleshooting Steps for Faults 387 thru 391
1.
With Ignition switch in OFF position, remove ECU power by pulling the ECU circuit breaker. Wait 10s
before resetting. Is fault active? If no, go to step 3. If yes, go to step 2.
2.
Contact Lycoming Engines to correct the calibration files and reflash the ECU. Is fault still active? If
no, go to step 3. If yes, replace the ECU.
3.
Clear Service faults using the FST by following the steps outlined in the “Access the Field Service
Tool” section in Appendix C or the latest revision of
SSP-118.