![Lycoming TEO-540-C1A Maintenance Manual Download Page 44](http://html.mh-extra.com/html/lycoming/teo-540-c1a/teo-540-c1a_maintenance-manual_1953585044.webp)
TEO-540-C1A Engine Maintenance Manual
05-20
© 2018 Avco Corporation. All Rights Reserved
Page 14
November 2018
TEO-540-C1A Engine Maintenance Manual
Visual Inspection Checklist for TEO-540-C1A Engines (Cont.)
Item
Comments
Findings/
Corrective Action
Done
Wiring Harness (Cont.)
Examine electrical connectors for
evidence of corrosion.
If corrosion is found,
disconnect, examine the
connector, and clean or
replace the connector as
required.
Make sure the wiring harnesses are
routed correctly and attached
securely and that there are no
broken, chafed or frayed wires or
damaged/broken sensors or
connectors.
Refer to Chapter 72-70.
Replace the wiring
harness if a wire is
broken, frayed or chafed
or if a sensor connector
is broken or damaged.
Refer to Appendix B in
this manual for wiring
harness connections.
Ensure that all engine wiring
harness cushion clamps are secure
and not worn or damaged.
Tighten any loose
clamps. Replace any
worn or damaged
clamps.
Turbocharger
Examine all V-band clamps to
ensure they are tight and
undamaged.
Refer to Chapter 72-40.
Make sure that all exhaust heat
shields are secure and undamaged.
Induction System
Make sure that the induction system
is in satisfactory condition. Ensure
that all clamps and hardware are
securely fastened and that there is
no evidence of leakage or staining.
Refer to the “Induction
System Inspection” in
Chapter 72-80.
In accordance with the aircraft
manufacturer’s instructions,
examine the induction air filter for
cleanliness, security, and
indications of damage.