Manual test of connection between sensor and repeater:
1.
Use this function to test whether a sensor added to the repeater is already or still
connected to the repeater.
2.
Set SW2 to ON.
3.
Press the test (learn) button of the sensor, which was added already to the
repeater. If the connection to the repeater is available, the repeater will sound a
long signal and the red LED light sup for one second.
4.
After having tested the connection of all required sensors to the repeater, set SW2
back to OFF.
Factory settings:
1.
Set SW3 to ON
2.
Press and keep pressed the (red) “Delete memory button” for at least 5 seconds. A
long signal sounds. This deletes all sensors and their activation/connection to the
XT2 control unit!
3.
Set SW3 back to OFF.
Note:
A repeater can be activated for one control unit (area) maximum and supports a
maximum of 80 sensors. If you try to add more than these 80, the control unit will
sound six short beeps.
You can
not
use the following sensors/devices with the wireless repeater: PSS
devices (wireless sockets, in-wall relays), PIR network camera, temperature
sensors, wireless relay, mini indoor siren, wireless repeater (cascading).
As long as a sensor learned to the repeater is able to transmit its signal strength
directly to the control unit, this (weaker) signal is shown in the web interface. You
can test the proper function of the sensor by increasing the sensor’s distance to
the control unit and performing a range test. If the signal strength now increases,
the sensor transmits via the repeater. In case of an alarm, the sensor will reach the
control unit one way or the other.