![Luminex Ethernet - DMX8 / WiFi User Manual Download Page 49](http://html1.mh-extra.com/html/luminex/ethernet-dmx8-wifi/ethernet-dmx8-wifi_user-manual_1948899049.webp)
Reseting the Ethernet DMX8/W wireless device
It can be sometimes useful to start on a default wireless device
configuration, by example when the Ethernet DMX8/W has be rented and
a user has set a password on it. To reload the factory set up of the
Ethernet DMX8/W, please use the front end display, and follow this
procedure:
•
enter the main menu by pressing “-”
•
Press “>” button to reach “Global settings” menu, and press enter
•
Press “>” to reach “RESET ACCESS POINT” menu, press enter
•
Confirm by pressing Enter
•
the wireless device is now rebooting
Please remind thus the default factory IP address (2.1.0.1). It is
also possible to reset the wireless device through LumiNet monitor
V.2
Application examples
Point to point
In that case we create a point to point link between 2 Ethernet DMX8/W
nodes, usually used to cross a river, between two buildings or to distribute
DMX data were you can't run DMX cables.
Thanks to the DMX8/W new firmware, you can plug a second desk to the
B Ethernet DMX8/W and run it as a backup desk, or as a second desk
controlling lights linked to the A Ethernet DMX8/W.
Always keep in mind you can't stream more than 8 universes
between two Ethernet-DMX 8/W on a 5Ghz link, 4 universes on a
2.4Ghz link, 8 universes on a 2.4Ghz link in unicast mode !
Ethernet - DMX8 / WiFi
Page 49 of 54