![Luminex Ethernet - DMX8 / WiFi User Manual Download Page 11](http://html1.mh-extra.com/html/luminex/ethernet-dmx8-wifi/ethernet-dmx8-wifi_user-manual_1948899011.webp)
UDP ports setting
The UDP ports are used to indicate the Ethernet ports number on which
the network socket has to listen for ArtNet data. 2 UDP ports are available
on the node, 1 for four universes. These numbers are indicated in Hex
value and the default is 0x1936. These values may only be changed by an
experienced network administrator.
Ethernet - DMX8 / WiFi
Page 11 of 54
Use the up down keys to change the value of
every digit separately.
Every digit can be a value between 0 and F
(hexadecimal).
Use the left right keys to change from edit
field.
Once the UDP port is set, press ENTER to go
to the confirmation screen.
In this confirmation screen you can choose
with the left right keys whether you want to
confirm your changes or cancel them.
Press ENTER in the convenient screen to
Confirm or to Cancel the UDP port setting.
> >
Enter
Enter
>>
<<
Enter
Enter
Network Config
< UDP port 1
UDP port 1
0x1936
Port 1: 0x1936
CONFIRM >
Port 1: 0x1936
< CANCEL