![Lumen Dynamics Group OmniCure LX400+ User Manual Download Page 42](http://html1.mh-extra.com/html/lumen-dynamics-group/omnicure-lx400/omnicure-lx400_user-manual_1947995042.webp)
- 37 -
LX400+ UV LED Spot Curing System
PIN #
Description
I/O
Location
20
SYNCOUT4(-)
O
Pin 20
21
EMPTY
Pin 20
22
STRT/STP3
I
Pin 22
23
STRT/STP4
I
Pin 23
24
TIMEIN
I
Pin 24
7.3
PLC Signal Descriptions
Pin 1 INTIN1
Analog input from 1.0VDC to 4.0VDC will set the output
intensity of channel 1 from 15% to 100% in 1%
increments. The following equation can be used to
determine the output intensity based on a voltage input;
y=(85x-40)/3
where;
x is the voltage input from 1.0V to 4.0V.
y is the output intensity in percent. Value round to
nearest percent.