![Lumen Dynamics Group OmniCure LX400+ User Manual Download Page 41](http://html1.mh-extra.com/html/lumen-dynamics-group/omnicure-lx400/omnicure-lx400_user-manual_1947995041.webp)
- 36 -
LX400+ UV LED Spot Curing System
7.2
PLC Connector
The rear panel of the main controller (ref.
has a PLC connection; it is a 24 pin terminal block connector,
which has the following pin-outs;
Table 5 PLC Connector Pin-Outs
PIN #
Description
I/O
Location
1
INTIN1
I
Pin 1
2
INTIN2
I
Pin 2
3
GND
Pin 3
4
ALARM(+)
O
Pin 4
5
SY)
O
Pin 5
6
SY)
O
Pin -6
7
SY)
O
Pin 7
8
SY)
O
Pin 8
9
EMPTY
Pin 9
10
STRT/STP1
I
Pin 10
11
STRT/STP2
I
Pin 11
12
FPLOCK
I
Pin 12
13
INTIN3
I
Pin 13
14
INTIN4
I
Pin 14
15
AGND
Pin 15
16
ALARM(-)
O
Pin 16
17
SYNCOUT1(-)
O
Pin 17
18
SYNCOUT2(-)
O
Pin 18
19
SYNCOUT3(-)
O
Pin 19