- 24 -
LX400+ UV LED Spot Curing System
5.2
Mode Control
5.2.1
Upon completion of start-up cycle press
MODE
button
to access timer, level and trigger control.
Note
: the controller will automatically go to the timer mode
upon start up.
5.2.2
The
MODE
button is sequential, depressing the button
will cycle through each control:
1. Press and release
– timer mode.
2. Press and release
– level mode.
3. Press and release
– trigger mode.
5.3
Timer Control
5.3.1
Controls the setting of the length of light emission time
from each individual LED head when the count down
(
cnt.d
) function (automatic mode) is selected from the
TRIGGER
control.
5.3.2
Press and release the
MODE
button to access the
timer control. The
TIMER
LED should light up (color
green) and the display window should read XXX.X
5.3.3
Press the channel select button of the installed
head(s).
5.3.4
Press and release the
UP/DOWN
button to increase or
decrease the timer in 0.1 second increments.
5.3.5
Press and hold the
UP/DOWN
button to rapidly
increase or decrease the timer value.