- 27 -
LX400+ UV LED Spot Curing System
Note:
In either manual or automatic control the DISPLAY shows
the channel selected only. To view other channels during
LED emissions press the desired CHANNEL button.
Note:
To disable a channel either set channel emission level to
OFF
(reference section
) or remove LED head from
rear panel.
5.7
LED Emission, Manual Control
5.7.1
In this mode the timer select function is disabled.
5.7.2
Press and release the
MODE
button until the
TRIGGER
LED on the front panel comes on (color
green).
5.7.3
Press and release the
UP
or
DOWN
button so the
display reads “
cnt.u
”.
5.7.4
Press and release the
MODE
button until the
LEVEL
LED on the front panel comes on (color green). Press
the channel select button of the installed LED head.
5.7.5
Press and release the
UP
or
DOWN
button to select
the emission intensity level %.
5.7.6
Press and hold the
START/STOP
button to start the
desired Emission time, the display will count up from 0
seconds.
5.7.7
Release the
START/STOP
button to end the desired
emission time. The display will return to 0 seconds.
5.8
LED Emission Automatic Control
5.8.1
Press and release the
MODE
button until the
TRIGGER
LED on the front panel comes on (color
green).