![Lumen Dynamics Group OmniCure LX400+ User Manual Download Page 15](http://html1.mh-extra.com/html/lumen-dynamics-group/omnicure-lx400/omnicure-lx400_user-manual_1947995015.webp)
- 10 -
LX400+ UV LED Spot Curing System
Head Model 400nm
Blue Light Hazard Radiance
(determined from table 5.5 of IEC 62471)
Distance Away From Head
Along Plane of Beam Axis (mm)
Distance Away From Head
Normal to Beam Axis (mm)
449
0
383
68
257
91
199
101
126
85
Head Model 400nm
Blue Light Hazard Radiance
(determined from table 5.4 of IEC 62471)
Distance Away From Head
Along Plane of Beam Axis (mm)
Distance Away From Head
Normal to Beam Axis (mm)
273
0
257
30
201
57
126
58
2.3.2
Exposure Hazard Values (EHVs)
Test Results
– Radiance Summations (watt/srm²)
(IEC62471)
Test
Results:
365nm Head
Test
Results:
385nm Head
Test
Results:
400nm Head
Exempt
Group
Specified
Max*
Blue Light
Hazard (table
5.5)
177
watt/sr-m² #
637
watt/sr-m² #
1257
watt/sr-m² #
100
watt/sr-m²
Weighted
Retina Visible
and Infrared
Thermal
Radiance
(table 5.5)
415
watt/sr-m²
6327
watt/sr-m²
12584
watt/sr-m²
622222