3-44
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
Enclosure and Component Installation
Status lights
Figure 3-33. COP status lights
The
FAULT
LED momentarily turns ON just after startup After the system starts up,
each light monitors a state as described in Table 3-4.
Table 3-5. Status lights on the COP module
Status
light
Color
Condition Indicates
FAULT
Red
ON
The system is booting or the system is in a failure
mode.
TA
Green
ON
A test relay has been operated on an LPM to test
the copper ADSL facilities.
MISC
Yellow
ON
The COP has detected a relay closure on one of
the seven pairs connected to the ALARM
connector.
FAC
Green
Yellow
ON
ON
The optical connection for the COP is operating
properly.
The optical connection for the COP has failed.
FAULT
TA
MISC
FAC
FAULT LED
FAC LED
TA LED
MISC LED