6-10
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
Hosted System Management
Monitoring the status of remote shelves
Sample alarm for input-relay closure status on any remote shelf
The following commands configure an alarm for input-relay closure on any remote
shelf in a hosted system:
HOST>
new alarm closed
HOST>
set enabled = yes
HOST>
set event = input-relay-closed
HOST>
write -f
HOST>
new alarm open
HOST>
set enabled = yes
HOST>
set event = input-relay-open
HOST>
write -f
If one of the alarms is triggered, the alarm action takes effect, and the
remote-shelf-stat
profile is updated. In addition, the status is accessible in the
output of the
alarm -s
command. For example, the following output shows contact
closure on shelf 2:
HOST>
alarm -s
Type Address State
Input Relay Closed { 2 0 1 } Active
Input Relay Closed { 2 0 2 } Active
Input Relay Closed { 2 0 3 } Active
Input Relay Closed { 2 0 4 } Active
Input Relay Closed { 2 0 5 } Active
Input Relay Closed { 2 0 6 } Active
Input Relay Closed { 2 0 7 } Active
Sample alarm for internal fan failure on shelf 2
The next commands set an alarm for failure of the internal fan unit on shelf 2:
HOST>
new alarm fan
HOST>
set enabled = yes
HOST>
set event = fan-failure
HOST>
set physical-address shelf = shelf-2
HOST>
write -f
If the alarm is triggered, the alarm action takes effect, and the
remote-shelf-stat
profile is updated. In addition, the status is accessible in the output of the alarm -s
command. For example:
HOST>
alarm -s
Type Address State
Fan Failure { shelf - 2 } Active