Enclosure and Component Installation
Route and connect the fibers and ground cable inside the enclosure
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
3
-15
Warning
Early models of the Stinger Compact Remote were installed with one-way
screws. If one-way screws are being removed or loosened with an SSTM14 tool,
sharp metal edges are created on the screw head that can result in injury. After
loosening or removal. Follow local guidelines when replacing one-way screws with
tribunal recessed head screws.
Route and connect the fibers and ground cable inside the
enclosure
Use the following procedure to route the fiber cable into the Stinger CR enclosure.
1
Feed the fiber cable through the watertight fitting on the bottom of the
enclosure. (See “Enclosure cable exit points” on page C-21 for the locations of
the watertight fittings on the bottom of the enclosure.)
2
Securely tighten the water tight fitting by hand.
3
Install a cable shield grounding harness to the fiber optic cable inside the
enclosure.
4
Attach the ground cable from the grounding harness to the grounding point on
the right side of the grounding bar located at the lower left side of the enclosure
(see Figure 3-10).
Figure 3-10. Enclosure fiber tray details
Use the following procedure to route and connect the fiber optics within the
enclosure.
1
Loosen the retaining screw on the fiber tray and slide the fiber tray forward.
2
Feed the fiber from the fiber cable up through the access slot near the back of the
fiber tray.
Caution
To avoid damage to the fiber, be sure to route the fiber behind the left
front mounting support for the fiber tray before feeding it up through the fiber
access slot.
Retaining screw
Fiber access slot
Splice tray retaining point
SC connectors
Fiber cable grounding point
Fiber tray mounting support