D-2
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
Safety-Related Electrical, Physical, and Environmental Information
Safety Instructions
7
Never install telecommunication wiring during a lightning storm.
8
Never touch un-insulated telecommunication wires or terminals unless they
have been disconnected at the interface.
9
Warning:
To avoid shock or injury, never touch un-insulated wiring or terminals
carrying direct current or ringing current, or leave this wiring exposed.
10
Warning:
To avoid shock and injury to service personnel, or electrical fire,
protect and tape wires and terminals carrying direct current or ringing current.
11
To avoid overheating the unit, never block the ventilation slots or openings in
this unit.
12
To avoid electrical fires, all fuses used in this product must be replaced with fuses
of the same type and rating.
13
The installation must have an independent frame ground drop.
!
14
Caution:
This unit has up to five (5) ±190 Vdc (RFT-V) input power feeders. To
reduce the risk of injury, all power feeds must be disconnected to completely
remove power from the system.
15
Warning:
Install only equipment identified in the applicable Lucent Technologies
Manual(s). Use of other equipment may result in improper connections of
circuitry which could cause fire or injury.
16
Warning:
Only use this product with telephone wiring protected by an AVAYA
3B or 3C Primary protector. See instruction manual.
17
Warning:
Invisible laser radiation may be present when the enclosure is open
and a fiber optic cable is disconnected. Avoid Direct Exposure to Beam.
18
Warning:
Un-terminated optical connections may emit laser radiation.
19
Do Not View With Optical Instruments.
20
The effective capacitance of this product is 0.27 µF between the connection
points for the conductors of the telecommunication network and 3.9 nF between
the connection point for one conductor of the telecommunication network and
earth.
21
At the time of installation, you must check that all circuits being connected are
RFT-V or RFT-C circuits.
22
At the time of installation the voltage rating of the wiring for the
telecommunication Network must be checked to determined if its adequate for
the normal RFT-V circuit Voltage, together with superimposed transients.