C-16
The Stinger® Compact Remote ATM DSLAM Getting Started Guide
Cables and Connectors
Cabling for the 48-port LPM with splitters
Figure C-7.
Stub cables for connection to the protection blocks
Cable and protection associations
The Stub cables are identified as OSP 1, OSP 2, and OSP 3. The cables connectors on
these cables are labeled P1 through P4 or P5, depending on the cable. The
connections on the protection blocks for these connectors are also labeled OSP 1,
OSP 2, OSP 3, and OSP 4. Use the color codes, labeling on the cables, and the
information in Table C-5 to connect the proper connector from the OSP cables to the
proper OSP connector on the protections blocks.
OSP 1 cable
OSP 2 cable
OSP 3 cable
P1
P2
P3
P4
P5
P1
P2
P3
P4
P5
P1
P2
P3
P4
Stub
Stub
Stub
Table C-5.
OSP cable binders, pairs, and protection block connections
Cable
Binder Pairs
Cable
Connector
Protection
block
Protection
block
Connector
LPM/
LIM
No.
2-wire
Circuits
4--wire
Circuits
OSP 1
Blue
1-25
P1
2
OSP 3
1
POTS 1-25
NA
OSP 1
Orange 1-23
P2
2
OSP 4
1
POTS 26-48
NA
OSP 1
Orange 24-25
P3
4
OSP 3
2
POTS 1-2
NA
OSP 1
Green
1-23
P3
4
OSP 3
2
POTS 3-25
NA
OSP 1
Green
24-25
P4
4
OSP 3
2
POTS 26-27
NA
OSP 1
Brown
1-21
P4
4
OSP 4
2
POTS 28-48
NA