Appendix D Reference Information
Quality of Service (QOS) Class Tables
D-34
255-700-239
PacketStar
®
PSAX 4500 Multiservice Media Gateway User Guide
, Issue 2
Release 8.0.0
The Alarm Status field on the Equipment Configuration window displays the
current status of all
PacketStar
I/O, server, and common equipment modules
in the PSAX system. The alarm status descriptions are provided in Table D-2.
Quality of Service (QOS) Class Tables
Table D-4 details the PSAX system support of defined ATM QoS classes.
Table D-2. Alarm Status Descriptions for PSAX Modules
Numb
er
Alarm Status
Module Type
Affected
Description
1
NoAlarm/Card-
Present
I/O
No module is inserted in the
chassis.
2
WrongCardType I/O
One type of module was config-
ured in this slot in the chassis,
but a different module now
occupies this slot.
3
LineFailed
All
The line has failed.
4
CardRemoved
All
A module has been configured
and then removed.
5
ReferenceClock-
Failed
Stratum
The timing reference clock has
failed.
6
CompositeClock-
Failed
Stratum
The timing composite clock has
failed.
7
Overload
Power Supply
The Power Supply is operating
under an overload condition.
8
Plus5vFailed
Power Supply
The 5 V Power Supply has
failed.
9
Plus120vFailed
Power Supply
The 120 V ac Power Supply has
failed.
10
Minus48vFailed
Power Supply
The -48 V dc Power Supply has
failed.
11
UnknownAlarm
I/O
The reason for failure is not
known.
12
CompleteClock-
Failed
Stratum
The timing complete clock has
failed.
13
BackplaneCir-
cuitryFailed
All
The chassis backplane circuit
board is not operating.
14
PowerFailed
Power Supply
Power failed