255-700-239
C-13
PacketStar
®
PSAX 4500 Multiservice Media Gateway User Guide
, Issue 2
Release 8.0.0
Appendix C Configuring In-Band Management
Using the Hybrid Connection Configuration
Select the
Site Specific Configuration> In-Band Management
menu
options.
Example:
Primary IP Address: 020.001.001.005
Primary IP Mask: 255.000.000.000
6
Set up in-band management connections on the CPU module of Node A
to a remote PSAX system:
For setting up an in-band connection from the DS3 module to the CPU
module, configure the DS3 module and bring the interface into service.
Select the
Connection Configuration > In-Band Management IP PVC >
Add Connection
menu options, configure the PVC to the FORECARD.
Example:
Slot:
Slot Number
VPI: VPIabIP Address: 020.001.001.002
Port:1VCI: VCIabIP Mask: 255.000.000.000
Channel: 1
Slot:
Slot Number
VPI: VPIacIP Address: 020.001.001.003
Port:1VCI: VCIacIP Mask: 255.000.000.000
Channel: 1
Slot:
Slot Number
VPI: VPIadIP Address: 020.001.001.004
Port:1VCI: VCIadIP Mask: 255.000.000.000
Channel: 1
Slot:
Slot Number
VPI: VPIaeIP Address: 020.001.001.005
Port:1VCI: VCIaeIP Mask: 255.000.000.000
Channel: 1
7
Set up in-band management connections on the CPU module of each of
the Nodes B,C,D,and E:
Example:
Node B
Slot:
Slot Number
VPI: VPIabIP Address: NMS net. addr
Port:1VCI: VCIabIP Mask: NMS net. mask
Channel: 1
Node C
Slot:
Slot Number
VPI: VPIacIP Address: NMS net. addr
Port:1VCI: VCIacIP Mask: NMS net. mask
Channel: 1
Node D
Slot:
Slot Number
VPI: VPIadIP Address: NMS net. addr