6. Configure the following module parameters:
a. STM-1 MSP SM/MM for ATM UNI 3
b. DSP2D Voice Server for AlgoSet6 and AAL2 Standard
7. Go to the Console Interface Main Menu> Site Specific Menu> V5 Inter-
face Configuration > V5 Interface Table > Add Interface command > At a
minimum, set 3 values:
a. Intf ID from 1 to 10
b. LE Intf field
c. Active Variant IDvalue
8. Apply the Create Interface command.
9. Go to the V5 Interface Configuration > Variant Table command> Add
Variant entry > enter values to V5 Interface Variant Configuration win-
dow.
10. Enter the V5 Variant ID that matches to the V5 Interface Configuration
value.
11. Apply Create Variant command> Bring Into Service.
12. On the V5 Interface Variant Configuration window, select Add Phys Chnl
Table to Variant command > Add PhysCChan Configuration Entry> V5
PhysCChan Cfg Tbl displays > Add PhysCChan Cfg entry > V5 PhysC-
Chanel Cfg window displays
13. On V5 PhysCChannel Configuration window, at a minimum enter val-
ues for these fields:
a. Enter Phys CChan Id fld values. For Protectgroup-1, always use 16.
For Protectgroup-2, use 15 or 31.
14. On the Configure CommCChan ID fld (local), enter a value higher than
0 to force the configLogical CChan ID (remote switch) field appear.
15. Select the Add V5 PhysCChan to table command.
16. Return to the V5 PhysCChannel Configuration Table > B to the
V5 Interface Variant Configuration window.
17. Do Add E1 Link Table to Variant command > Displays V5 E1 link Cfg Tbl
> Add E1Link Config Entry >
18. At a minimum, enter values for these fields: Link ID and Phys ID.
19. Change the Admin Status field to value Unblocked.
20. Select the Add V5E1Link to table command.
21. Apply the Admin Status command.
22. On V5 Interface Variant Configuration window > Add DL Table to Vari-
ant command > V5 Data Link Configuration Table displays.
23. Select Add Data Link Configuration Entry command > V5 Data Link
Configuration window, set values.