RS485 communication
182
Address
Parameter
Scale Unit R/W
Allotment for Bits
0x0005
Freq.
Reference
0.01
Hz R/W Starting freq. - Max. freq.
0x0006 Run Command
-
-
R
B15, B14, B13 : Reserved
B12, B11, B10, B9, B8 : Freq. command
0 : DRV-00, 1 : Not Used,
2-8 : Multi-Step frequency 1-7
9 : Up, 10 : Down, 11 : Up-Down Zero
12 : V0, 13 : V1, 14 : I,
15 : V0+I, 16 : V1+I, 17 : JOG,
18 : PID, 19 : Communication,
20-31 : Reserved
B7, B6 : Run Command
0 : Terminal, 1 : Keypad, 3 : Communication
R/W
B5
Reserved
B4
Emergency stop (0->1)
B3
Fault reset (0->1)
B2
Reverse run (0->1)
B1
Forward run (0->1)
B0
Stop (0->1)
0x0007
Acceleration
Time
0.1
sec R/W See Function List
0x0008
Deceleration
Time
0.1
sec R/W See Function List
0x0009 Output Current
0.1
A
R
See Function List
0x000A
Output
Frequency
0.01
Hz
R
See Function List
0x000B Output Voltage
0.1
V
R
See Function List
0x000C
DC Link
Voltage
0.1
V
R
See Function List
0x000D Output Power
0.1
kW
R
See Function List
0x000E Inverter Status
-
-
-
B0
Stop
B1
Forward running
B2
Reverse running
B3
Fault (Trip)
B4
Acceleration
B5
Deceleration
B6
Speed arrived
B7
DC Braking
B8
Stopping
B9
Not Used
B10 Brake open
B11 Forward run command
B12 Reverse run command
B13 REM. R/S
B14 REM. Freq.
B15 Reserved
www.barghmaher.ir
Summary of Contents for iG5H Series
Page 13: ...www barghmaher ir ...
Page 22: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O www barghmaher ir ...
Page 23: ...10 Installation Wiring www barghmaher ir ...
Page 50: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern www barghmaher ir ...
Page 173: ...Protective functions 160 www barghmaher ir ...
Page 219: ...206 DECLARATION OF CONFIRMITY www barghmaher ir ...
Page 223: ...210 www barghmaher ir ...