Advanced functions
102
►
When F65 is 1: It is increased as many as step frequency set as F66 at the rising edge
of multi-function input set as UP and when up-down is defined, it saves frequency at the
falling edge. It is decreased as many as step frequency set as F66 at the falling edge of
rising edge of multi-function input set as DOWN and when up-down is defined, it saves
frequency as the falling edge. In this case, while multi-function input set as UP or
DOWN is defined, if stop command is inputted, previous falling edge value is saved and
if multi-function input is not defined, present frequency is not saved. The accel/decel
time is same with when stetted as
“0”.
►
When F65 is 2: It is increased as many as step frequency set as F66 at the rising edge
of multi-function input set as UP and if it is activated for 3 second, it operates like
something set as
“0”. It is decreased as many as step frequency set as F66 at the rising
edge of multi-function input set as DOWN and if it is activated for 3 second, it operates
like something set as
“0” and the accel/decel time is same with when stetted as “0”.
Because of UP or DOWN, when the input is entered again before it is increased as many as 1
step frequency, the input is ignored and the saved frequency is also frequency of the
inactivated moment
www.barghmaher.ir
Summary of Contents for iG5H Series
Page 13: ...www barghmaher ir ...
Page 22: ...9 Installation Wiring Installation 2 3 Terminal wiring Control I O www barghmaher ir ...
Page 23: ...10 Installation Wiring www barghmaher ir ...
Page 50: ...37 Programming Keypad Basic operation Basic Ops Wiring Operating pattern www barghmaher ir ...
Page 173: ...Protective functions 160 www barghmaher ir ...
Page 219: ...206 DECLARATION OF CONFIRMITY www barghmaher ir ...
Page 223: ...210 www barghmaher ir ...