3 - 27
(14) DeSOx switch
When the engine sends the signal that DeSOx
is required to the instrument panel, the indicator
①
below flashes at 1Hz on the instrument panel.
If pressing the upper side of the switch for more
than three seconds
, it will send the signal to the
engine to run the DeSOx process.
The following safety conditions must be met
before pressing the DeSOx switch.
- FR shuttle lever is in neutral,
- Parking brake is engaged,
- PTO switch is in “OFF” position.
When the DeSOx is activated, the indicator
①
on
the instrument panel flashes during the process.
If you want to stop the process while the DeSOx
is running, press down the lower part of the
DeSOx switch.
Cabin
DeSOx switch
▶
If it is not strictly necessary, do not exiting from the safety conditions or stopping
the process to prevent thermal stress on the after-treatment system (ATS).
▶
If the thermal treatment has been stopped manually, the engine must be left
running at low idle rpm at least for 5 minutes in order to protect the ATS.
▶
If the DeSOx switch is press down for more than 10 seconds intentionally or not,
the Engine Control Management(ECM) will set a fault and does not allow forced
thermal treatment.
Caution
1
Roll-bar
DeSOx switch
Summary of Contents for XP8084
Page 1: ...LS TRACTOR OPERATOR S MANUAL XP8084 XP8094 XP8101 ...
Page 2: ......
Page 4: ......
Page 12: ......
Page 70: ......
Page 80: ...3 10 SCR inducement strategy Low DEF level ...
Page 81: ...3 11 SCR inducement strategy poor DEF quality ...
Page 82: ...3 12 SCR inducement strategy SCR System tampering detection ...
Page 188: ......
Page 261: ...5 73 Attachment ...
Page 262: ......
Page 280: ......
Page 282: ...8 2 2 Roll bar type Unit mm When applying front tire 12 4 24 8PR rear tire 16 9 34 8PR ...
Page 287: ......
Page 288: ......