![LONGHORN LHD8003 Installation Manual Download Page 8](http://html1.mh-extra.com/html/longhorn/lhd8003/lhd8003_installation-manual_1938631008.webp)
4. PGM Connection
The max load of PGM output is DC50V/500mA. Boolean value is output with PGM connected with GND of
main board.
Wired Devices Connection
The system supports different kinds of wired detectors with EOL resistance. Please connect as
following:
5
.
2. AUX Power Output Terminal
AUX supplies power output for wired detectors(AC Operated: 10-12V, Battery Operated: 6-8V, max
current: 100mA. It may cause abnormal working for wired detector under low battery).
3. Telephone Line Connection
Connect the telephone line to the telephone line terminal block “LINE_IN” on the main board.
And connect the telephone or fax machine to the telephone line terminal block “LINE_OUT” .
Figure - -
9
Figure -
-
10
For N/C detector:
N/C detector
For N/O detector:
N/O detector
-11-
-12-
N/O Detector
N/C Detector
Siren
Detector
Device Under Control
External Power
Telephone
Telephone Line
Figure - -
8
◆
Re-check the wiring and make sure all connection is correct.
◆
Connect the AC power adaptor and plug the backup battery. The control panel can not be initialized by only
battery.
◆
Parameters of power adaptor: Input: 100V-240VAC 50/60HZ 0.5A, Output: 12VDC 1.5A
.
Backup battery: 7.2V 1800mAh NimH rechargeable, 24hours is required for full recharge which can last
around 8 hours for this system under standby situation. After low battery warning, it can work for around
30 minutes.
◆
The system will keep the time and date with time chirp powered. If the power of time chirp runs out, you
need to re-set the time manually. See the Figure:
◆
After powering up and initialization, it beeps shortly and requires to input time and date.
◆
The icon will move to next automatically after each input. Press “
*
” to exit. After complete input, press “#”
to confirm. If the input is not finished, and meanwhile “
*
” is pressed, it will display on the LCD “Invalid
Set”. Please press “
*
” to re-input it.
◆
With GSM module connected, time will set by itself by searching the network, which may take 1-2 minutes.
1. Set Date
0 1 / 0 1 / 2 0 0 0
2. Set Time
0 0 : 0 0
4.3.4 Power Connection
AC power must be connected for initialization. Or else it can not be initialized with just backup
battery.
Note
Summary of Contents for LHD8003
Page 2: ...CREATING SECURITY SOLUTION...