iID  address  can  be  set  for  each  control  panel  so  that  the  CMS  can  identify.  Different  ID  must  be  set  for 

different control panels, which is 4-8 digits utmost with default as 1234.
To edit/delete ID:

1.  From the main menu, select 

Programming”→

#”

→ Comm.”→

#”

Comm

Account

” 

 “#”.

2.  Press the navigation key to select 

Panel ID

” 

 “#”.

3.  The former ID will display on the LCD, press 

“#” 

with

 

icon

 

to

 

input

 

new

 

ID

.

4.  ID can be 4-8 utmost ending with 

“#”. 

Press

 “

*

” 

to

 

delete

 

it

 

or

 

exit

Press

 “#” 

to

 

confirm

.

Line Monitor

The function of line monitor can be on or off. If the function is turned on, it will display on the LCD.
To set line monitor:

1.  From the main menu, select 

Programming”→

“#”

Comm.”→

“#“

Comm. Option”→

 

Line Monitor

“#”.

2.  Press the navigation key to select 

ON

” 

or

 “

OFF

” 

and

 

confirm

 

with

 “#”.

3.  Press 

“#” 

to

 

exit

.  

Test Interval

The  Periodic  Test  is  a  test  transmission  the  system  sends  to  notify  the  central  station  that  its  reporting 
capability is fully functional. And the test periodic test interval can be adjusted.

To set test interval:

1.  From the main menu, select 

Programming”→ 

“#”

→ 

Comm.”→ 

“#”

→ 

Test Interval

” 

“#”.

2.  Press the navigation key to select CMS ending with 

“#”.

3.  Then press the navigation key to select different period or type, ending with 

“#”.

4.  Press 

*

” 

to

 

exit

-41-  

-42-  

First Test

First test interval means the time for first periodic test to start.
To set first test:

1.  From the main menu, select 

Programming”→

#

→ Comm. 

O

ption”→

#”

→ First Test

” 

     

 “#”.

2.  Press the navigation key to select the CMS ending with 

“#”.

3.  Press the navigation key to select different time ending with 

“#”.

Call Attempts

The call attempts option determines the number of times the system tries to call a telephone number before 
moving on to the next number in sequence. It will not dial again if it exceeds the attempts.

 

“ ”

Comm. ”→ 

“#”

 

 

 

To set call attempts:

1.  From the main menu, select 

Programming”→ 

“#

”→

Comm. ”→ 

“#”

→ 

Comm. Option”→ 

“#“

→ 

Call Attempts

” 

     

 “#”.

2.  Press 

“#” 

to

 

edit

 

it

 

with

 

icon

 

flash

 

as

 

indication

.

3.  Set the attempts(1-30times).

4.  Press 

*

” 

to

 

exit

.

Ring Attempts

The ring attempts means the ring times before the phone hangs up. If it is set as 

0

”, 

it

 

means

 

no

 

remote

 

control

 

by

 

call

 

for

 

the

 

system

.

To set ring attempts:

1.    From  the  main  menu,  select 

Programming”→  

“ #”

Comm.  ”→  

“ #”

→  

Comm.  Option”→  

“ #

”→  

Ring 

      Attempts

” 

 “#”.

2.  Press 

“#” 

to

 

edit

 

with

 

icon

 

indication

.

3.  Set the call attempts(1-9 times, 0 means no remote control by call).
4.  Press 

*

” 

to

 

exit

.

GSM Option

It includes SMS Center, SMS Ack and SMS Confirm

If

 

SMS

 

Ack

 

is

 

turned

 

off

then

 

it

 

is

 

not

 

available

 

for

 

control

 

panel

If

 

SMS

 

confirm

 

is

 

turned

 

off

then

 

SMS

 

receipt

 

is

 

not

 

available

SMS Ack:
1.  From the main menu, select 

Programming”→ 

“#“

Comm. ”→ 

“#”

→ 

Comm. Option”→ 

“#”

→ 

GSM

 

Option”

 

     

→ 

“#“

→ 

SMS  Ack

” 

“#”.

2.  Press the navigation key to select 

ON

” 

or

 “

OFF

” 

and

 

confirm

 

with

 “#”.

3.  Press 

*

” 

to

 

exit

.

CMS Cooperation

 SMS Confirm:

1.  From the main menu, select 

Programming”→ 

“#”

Comm. ”→ 

“#”

→ 

Comm. Option”→ 

“#”

→ 

GSM

 

Option”

    

 

→ 

“#”

→ 

SMS Confirm

→ 

“#”

.

2.  Press the navigation key to select 

ON

” 

or

 “

OFF

” 

and

 

confirm

 

with

 “#”.

3.  Press 

*

” 

to

 

exit

.

With this function available, if the alarm info is uploaded to one CMS, then it will not dial or send message to 

another CMS. While with this function closed, then the alarm will be uploaded to both CMS.

To set CMS cooperate optional:

1.  From the main menu, select “Programming”

 “

#”

“Comm.”

 

“#”

 

Comm. Option”

 

CMS cooperation

 

    

“#”.

2.  Press the navigation key to select 

ON

” 

or

 “

OFF

” 

and

 

confirm

 

with

 “#”.

3.  Press 

*

” 

to

 

exit

.

Control Panel ID

Summary of Contents for LHD8003

Page 1: ...86 755 33265388 Website http www csst longhorn com E mail helen p csst com TH ST TH THE 4 BUILDING 1 FLOOR OF THE 5 BUILDING NEW AND HIGH TECHNOLOGY PARK GUANGMING WANDAIHENG BAOAN SHENZHEN CHINA LHD...

Page 2: ...CREATING SECURITY SOLUTION...

Page 3: ...Address CMS 2 Phone NO SMS Center 1 SMS Center 1 Address SMS Center 1 Phone NO SMS Center 2 SMS Center 2 Address SMS Center 2 Phone NO 02 PACKING LIST Note It should include screws 4pcs EOL resistanc...

Page 4: ...1 2 Arm Stay 5 5 6 6 7 7 8 8 8 9 9 10 10 12 13 13 13 14 14 15 15 15 15 16 18 19 19 20 21 22 22 22 23 23 23 24 7 1 3 Disarm 7 2 Arm Disarm via Phone 7 3 Arm Disarm via SMS 7 4 Trigger Alarm via Keypad...

Page 5: ...lay intelligent voice guide operation Periodic supervision for wireless PIR and magnetic switch PSTN or GSM dialing or SMS message send for alarm optional Upload and download function optional 255 eve...

Page 6: ...ng guidelines 1 Whenever possible mount the panel centrally in relation to wireless sensors 2 Avoid installation in close proximity to sources of high noise or radio frequency interference for example...

Page 7: ...wireless detector magnetic switch siren and keyfobs etc Step 6 Test the communication signal of chosen mounting location Step 7 Permanently install the control panel and transmitters Figure 5 TX TX R...

Page 8: ...adaptor and plug the backup battery The control panel can not be initialized by only battery Parameters of power adaptor Input 100V 240VAC 50 60HZ 0 5A Output 12VDC 1 5A Backup battery 7 2V 1800mAh Ni...

Page 9: ...ct attention to the depth of screws to make sure easy hang and tamper switch work normally There are 2 tamper switches front tamper and rear tamper Compress the tamper switch while installing If the c...

Page 10: ...g symbols or marks Selected for multiple choice Unselected for multiple choice Selected for single choice Unselected for single choice Counting down System trouble Display of alarm events Alarm List S...

Page 11: ...ent alarm way 1 For entry exit zone only during arm away and arm stay will the zone be triggered with alarm delay 2 For active zone only during arm away will the zone be triggered with alarm delay 3 W...

Page 12: ...will auto release the code While if the code is locked after alarm auto release must be available after system re intialization or within 30 minutes If the code is input wrong the voice will guide Wr...

Page 13: ...alance for SIM card Commu nication Trouble Trouble There are 8 types of zones entry exit zone active zone perimeter zone panic zone fire zone gas zone tamper zone and duress zone There are 22 zones zo...

Page 14: ...ng Arm or disarm is not available during programming or trouble query Via keypad requires installer code while via keypad requires no code Exit Delaying s When the exit delay ends the voice guide will...

Page 15: ...isarmed alarm log eliminated 2 Disarm with alarm status saved Input the code except installer code ending with just the arm LED turns from Red to Green with voice guide Disarmed Disarm 2 0 1 2 2 0 1 0...

Page 16: ...r confirm Press to quit programming to previous menu Or it will return to previous automatically with no operation within 1 minute 27 28 Through this operation all communication buffers are cleared an...

Page 17: ...confirm or press to quit To set duress code 1 From the menu select Code Set Duress Code Duress Code Set While you disarm with duress code it will indicate Disarm on site but will dial or send alarm in...

Page 18: ...digits utmost Press to finish Or if no figure is input and is pressed directly the number will be deleted Voice Phone Interface Set It enables you to select PSTN or GSM as dialling way To set voice ph...

Page 19: ...n finished Siren test is strongly recommended periodically for safety which includes wired siren wireless siren and built in siren To test siren 1 From the menu select Service 2 Press the navigation k...

Page 20: ...it is registered the info will display on LCD If it isn t registered it will indicate as unknown signal 4 Press to quit after test finish GSM Test To ensure the validity of GSM communication please te...

Page 21: ...21 22 wired zones Zones No 17 and 19 To set siren function 1 From the main menu select Programming Device Zone Zone Siren Set 2 Use the navigation key to select the zone ending with 3 Then use naviga...

Page 22: ...nt If the function of Send for service is closed the trouble info will not be sent during enter ir quit programming or zone bypass It will send all event as default 39 40 To send for alarm 1 From the...

Page 23: ...ttempts option determines the number of times the system tries to call a telephone number before moving on to the next number in sequence It will not dial again if it exceeds the attempts Comm To set...

Page 24: ...tion Exit Delay S System 2 Press to edit with icon indication 3 Set the exit delay 0 300s 4 Press to finish and to exit Supplementary Entry Delay The Supplementary Entry Delay is a pre alarm feature t...

Page 25: ...While before the message is sent to the station and the telephone line recovers connected well the message will be cancelled Or if the message for Line loss is sent to the station successfully before...

Page 26: ...rm stay press 2 for disarm press 3 For alarm press 5 Turn on site siren press 6 turn off site siren press 7 for hang up please press 0 repeat Chapter 9 Telecontrol via Phone or SMS Pressing any key du...

Page 27: ...to the set phone number or SMS center for alarm or system trouble through Contact ID For example the control panel ID is 1234 when fire alarm disarm or zone trouble occurs it will send SMS as followi...

Page 28: ...et the incorrect telephone number User telephone is busy during alarm Few ringing attempts lead the system to hang up the phone automatically Battery is drained Enroll remote controller without progra...

Page 29: ...tenance may lead to the system disable Weekly testing is necessary to ensure the system work normally Chapter 12 Warranty and Limitations 53 54 Appendix 1 System Default Parameters No Setting Item Par...

Page 30: ...Ent Delay Output Trigger PGM Cut off Clear Users Del Superv SV CMS SMS Zone Trb Ind Call Back Reg Dis En Ex Per Line Loss TX Interface Auto ON OFF Wired Test WL Test Built in Test Clear WL Clear Sing...

Page 31: ...Zone 1 WL Register 1 By Code Learn 2 By Code Input 2 Clear WL 1 Clear Single 2 Clear All 3 Set zone Type 5 Chime Zone Set 4 Zone Siren Set 2 Keyfobs 1 Keyfob Register 1 By Code Learn 2 By Code Input...

Page 32: ...e entry exit zones active zones perimeter 24 hour zone No matter armed or disarmed it is in valid detecting status It is usually used in fire alarm duress alarm and other emergent alarm which can be c...

Page 33: ...Appendix 5 Zone Type Setting Figure Zone NO Installation Position Type Bypass or not 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 61...