LONGHORN LHD8003 Installation Manual Download Page 21

To register by code input:

1.  Select 

Programming”→

#”

"

Device”→

#”

"

Zone”

"

WL.  Register”→

#”  

By    Code  Input

” .

2. If the code is input before, it will remind if you want to re-register, press 

“#” 

to

 

continue

or

 “ ” 

to

 

exit

3. Input the ID, ending with 

“#”. 

4. Press 

“ ” 

to

 

quit

 .

“ #”

*

*

This enables you to remove the wireless devices by clearance. For the supervision function. If the device 

is removed without clearance, the system will alarm for device loss.

To clear WL:

1. Select 

Programming

“#”

Device”→

“#”

Zone”

Clear WL.” →

“#”, 

select

 “

Clear Single

” 

or

 

    

Clear All

”. 

2. If 

Clear Single

”, 

select

 

the

 

zone

 

number

 

ending

 

with

 “#”. 

While

 “

Clear all

” 

means

 

to

 

clear

 

all

 

enrolled

 

     wireless

 

transmitters

.

“#”

Clear WL

1. WL Zone 1
    Registered!
    Save?
    Zone ID:
    012123

1. WL. Zone1
                        

 

 

s

1. By Code Learn

2. WL. Zone 2

3. WL. Zone 3

1.WL. Zone 1

Zone Type 

For specific zone type definition, please refer to 6.1.
To set zone type:  

1. From the main menu, select 

Programming”→

#”

→ Device”

→ Zone”→

#”

→ Set Zone Type”→

#” . 

2. Press the navigation key to select the zone you desire to set ending with 

“#”, 

and

 

then

 

select

 

the

 

zone

 

type

    for

 

it

 

ending

 

with

 “ #” 

to

 

save

 

it

3. Press 

*

 

to

 

exit

Zone Siren Function 

It enables the  ser to active or mute external siren for some zone. 

Active

” 

enables

 

the

 

siren

 

to

 

buzzer

 

during

 

u

alarm

while

 “

Mute

” 

enables

 

the

 

siren

 

dummy

This

 

function

 

is

 

available

 

for

 

Zones

 

No

. 1-16(

wireless

 

zones

), 

21-22(

wired

 

zones

Zones

), 

No

. 17 

and

 1

9

.

To set siren function:

1. From the main menu, select 

Programming”→

“#”

Device”

Zone”→

“# ”

Zone 

Siren Set”→

“#”.

.

 

 

“#”

“#”

2. Use the navigation key to select the zone ending with 

“#”.

3. 

Then use navigation key to 

Active

” 

or

 “

Mute

” 

the

 

siren

 

ending

 

with

 “#”

“#”

Keyfob 

Register

4. 

Press 

*

” 

to

 

exit

.

Chime Zone

It is only available for enter/exit zones to enable the 

Welcome Function

”. 

During

 

disarm

trigger

 

the

 

zone

the

 

voice

 

of

 “

Welcome to intelligent alarm system

!” 

will

 

be

 

given

 

off

To set chime zone:

1. 

From the main menu, select 

Programming”→

“#”

Device”

Zone”→

“#”

Chime Zone S

et

”→

“#”.

2. 

Press the navigation key to select the zone NO. ending with 

“#”.

3. 

Then press the navigation key to select 

ON

” 

or

 “

OFF

” 

ending

 

with

 “#”.

4. 

Press 

“ ” 

to

 

exit

*

Keyfob Register

Same as wireless zones, please refer to that.

Clear 

Same as wireless zones, please refer to that.

Wireless Siren 

Same as wireless zones, please refer to that.

Delete Wireless Siren 

Same as wireless zones, please refer to that.

Activate/Mute Siren 

It enables the siren(built-in siren, external wired siren or wireless siren) to be on or off.
To activate or mute siren:

1. From the main menu, select 

Programming”→

#”

→ Device”→

#“

→ Siren”→

#”

 

.

2.  Press  the  navigation  key  to  select  the  siren  type:  Built-in  Siren,  Wired  Siren,  or  Wireless  Siren  ending 

    with 

“#”.

3. Then press the navigation key to select 

ON

” 

or

 “

OFF

”.

4. Press 

*

” 

to

 

exit

.

Siren Cut-off 

Siren  cut-off  is  the  period  of  time  the  sirens  are  activated  after  an  alarm  has  occurred,  which  can  be  set 
from 0 to 30 minutes.

”→

Activate/Mute” →

“#”

-37-   

-38-  

Summary of Contents for LHD8003

Page 1: ...86 755 33265388 Website http www csst longhorn com E mail helen p csst com TH ST TH THE 4 BUILDING 1 FLOOR OF THE 5 BUILDING NEW AND HIGH TECHNOLOGY PARK GUANGMING WANDAIHENG BAOAN SHENZHEN CHINA LHD...

Page 2: ...CREATING SECURITY SOLUTION...

Page 3: ...Address CMS 2 Phone NO SMS Center 1 SMS Center 1 Address SMS Center 1 Phone NO SMS Center 2 SMS Center 2 Address SMS Center 2 Phone NO 02 PACKING LIST Note It should include screws 4pcs EOL resistanc...

Page 4: ...1 2 Arm Stay 5 5 6 6 7 7 8 8 8 9 9 10 10 12 13 13 13 14 14 15 15 15 15 16 18 19 19 20 21 22 22 22 23 23 23 24 7 1 3 Disarm 7 2 Arm Disarm via Phone 7 3 Arm Disarm via SMS 7 4 Trigger Alarm via Keypad...

Page 5: ...lay intelligent voice guide operation Periodic supervision for wireless PIR and magnetic switch PSTN or GSM dialing or SMS message send for alarm optional Upload and download function optional 255 eve...

Page 6: ...ng guidelines 1 Whenever possible mount the panel centrally in relation to wireless sensors 2 Avoid installation in close proximity to sources of high noise or radio frequency interference for example...

Page 7: ...wireless detector magnetic switch siren and keyfobs etc Step 6 Test the communication signal of chosen mounting location Step 7 Permanently install the control panel and transmitters Figure 5 TX TX R...

Page 8: ...adaptor and plug the backup battery The control panel can not be initialized by only battery Parameters of power adaptor Input 100V 240VAC 50 60HZ 0 5A Output 12VDC 1 5A Backup battery 7 2V 1800mAh Ni...

Page 9: ...ct attention to the depth of screws to make sure easy hang and tamper switch work normally There are 2 tamper switches front tamper and rear tamper Compress the tamper switch while installing If the c...

Page 10: ...g symbols or marks Selected for multiple choice Unselected for multiple choice Selected for single choice Unselected for single choice Counting down System trouble Display of alarm events Alarm List S...

Page 11: ...ent alarm way 1 For entry exit zone only during arm away and arm stay will the zone be triggered with alarm delay 2 For active zone only during arm away will the zone be triggered with alarm delay 3 W...

Page 12: ...will auto release the code While if the code is locked after alarm auto release must be available after system re intialization or within 30 minutes If the code is input wrong the voice will guide Wr...

Page 13: ...alance for SIM card Commu nication Trouble Trouble There are 8 types of zones entry exit zone active zone perimeter zone panic zone fire zone gas zone tamper zone and duress zone There are 22 zones zo...

Page 14: ...ng Arm or disarm is not available during programming or trouble query Via keypad requires installer code while via keypad requires no code Exit Delaying s When the exit delay ends the voice guide will...

Page 15: ...isarmed alarm log eliminated 2 Disarm with alarm status saved Input the code except installer code ending with just the arm LED turns from Red to Green with voice guide Disarmed Disarm 2 0 1 2 2 0 1 0...

Page 16: ...r confirm Press to quit programming to previous menu Or it will return to previous automatically with no operation within 1 minute 27 28 Through this operation all communication buffers are cleared an...

Page 17: ...confirm or press to quit To set duress code 1 From the menu select Code Set Duress Code Duress Code Set While you disarm with duress code it will indicate Disarm on site but will dial or send alarm in...

Page 18: ...digits utmost Press to finish Or if no figure is input and is pressed directly the number will be deleted Voice Phone Interface Set It enables you to select PSTN or GSM as dialling way To set voice ph...

Page 19: ...n finished Siren test is strongly recommended periodically for safety which includes wired siren wireless siren and built in siren To test siren 1 From the menu select Service 2 Press the navigation k...

Page 20: ...it is registered the info will display on LCD If it isn t registered it will indicate as unknown signal 4 Press to quit after test finish GSM Test To ensure the validity of GSM communication please te...

Page 21: ...21 22 wired zones Zones No 17 and 19 To set siren function 1 From the main menu select Programming Device Zone Zone Siren Set 2 Use the navigation key to select the zone ending with 3 Then use naviga...

Page 22: ...nt If the function of Send for service is closed the trouble info will not be sent during enter ir quit programming or zone bypass It will send all event as default 39 40 To send for alarm 1 From the...

Page 23: ...ttempts option determines the number of times the system tries to call a telephone number before moving on to the next number in sequence It will not dial again if it exceeds the attempts Comm To set...

Page 24: ...tion Exit Delay S System 2 Press to edit with icon indication 3 Set the exit delay 0 300s 4 Press to finish and to exit Supplementary Entry Delay The Supplementary Entry Delay is a pre alarm feature t...

Page 25: ...While before the message is sent to the station and the telephone line recovers connected well the message will be cancelled Or if the message for Line loss is sent to the station successfully before...

Page 26: ...rm stay press 2 for disarm press 3 For alarm press 5 Turn on site siren press 6 turn off site siren press 7 for hang up please press 0 repeat Chapter 9 Telecontrol via Phone or SMS Pressing any key du...

Page 27: ...to the set phone number or SMS center for alarm or system trouble through Contact ID For example the control panel ID is 1234 when fire alarm disarm or zone trouble occurs it will send SMS as followi...

Page 28: ...et the incorrect telephone number User telephone is busy during alarm Few ringing attempts lead the system to hang up the phone automatically Battery is drained Enroll remote controller without progra...

Page 29: ...tenance may lead to the system disable Weekly testing is necessary to ensure the system work normally Chapter 12 Warranty and Limitations 53 54 Appendix 1 System Default Parameters No Setting Item Par...

Page 30: ...Ent Delay Output Trigger PGM Cut off Clear Users Del Superv SV CMS SMS Zone Trb Ind Call Back Reg Dis En Ex Per Line Loss TX Interface Auto ON OFF Wired Test WL Test Built in Test Clear WL Clear Sing...

Page 31: ...Zone 1 WL Register 1 By Code Learn 2 By Code Input 2 Clear WL 1 Clear Single 2 Clear All 3 Set zone Type 5 Chime Zone Set 4 Zone Siren Set 2 Keyfobs 1 Keyfob Register 1 By Code Learn 2 By Code Input...

Page 32: ...e entry exit zones active zones perimeter 24 hour zone No matter armed or disarmed it is in valid detecting status It is usually used in fire alarm duress alarm and other emergent alarm which can be c...

Page 33: ...Appendix 5 Zone Type Setting Figure Zone NO Installation Position Type Bypass or not 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 61...