LONGHORN LHD8003 Installation Manual Download Page 32

Table 2: Contact ID Table of Event Codes

CID Code

Definition

Operation using keypad without user code, such as arm-away, from disarm to arm-stay

Arm/disarm using master code, by keypad, phone or SMS

Arm/disarm using temporary code, by keypad, phone or SMS

Arm/disarm using the correspondent user code, by keypad, phone or SMS

Arm/disarm by keyfob

Arm/disarm by phone number 1-4 during alarm

Auto arm/disarm

Duress alarm by user 98,with “Disarm” indication on-site

Program with installer code

00

01

02

03

04

05~08

11~16

21~24

30

Appendix 3: Communication Protocol and Codes

Table 1: Contact ID Event Code

Definition

Panic  Alarm   

Fire  Alarm

Duress  Alarm

Perimeter  Alarm

Active  Alarm

Entry/Exit  Alarm

Panel anti-tamper alarm or tamper zone alarm

Gas  Alarm

AC Power Failure

Low Battery

Reset as Default

Line Loss

Detector Loss

Low Battery for Detector

Arm/Disarm

Arm Stay

Mute Siren

Auto Arm/Disarm Failure

Cancel Alarm

Zone bypass operation, Bypass all or cancel bypass for  User 99

Test Report

Enter Programming

Exit Programming

CID Code

100

110

121

131

132

134

137

151

301

302

311

351

381

384

401

406

441

455

521

570

602

627

628

-59-

-60-  

Detector: 

physical  methods  and  output  switch  signals  or  wireless  signals  to  the  system  for  disposal,  then  output 
alarm signals, such as infrared detector, smoke detector, etc.

Zone:

An area of the detection range of one or one group detectors.

Bypass: 

Close one of the zones temporarily, so that it can not alarm while act in the zone.

Arm Away

The armed status while going out. All the zones without bypass are in armed status.

Arm Stay: 

The armed status at night. All the zones are in armed status except active zones.

Disarm

Close the entry/exit zones, active zones, perimeter 

24  hour  zone:

  No  matter  armed  or  disarmed,  it  is  in  valid  detecting  status.  It  is  usually  used  in  fire 

alarm, duress alarm and other emergent alarm which can be cancelled only by password holder.

CMS

It  is  an  alarm  receiving  station,  to  which  the  alarm  controller  sends  out  alarm  information  via 

telephone line when alarm occurs. The station will take corresponding actions after receiving the alarm.

Entry Delay:

 

A period for user to enter detection area, activate the delay zone and disarm before the 

system  alarms.  During  the  period,  user  can  activate  several  specified  zones  (entry  zone)  without  alarm 
immediately. While exceeding the time, the system alarms if not disarmed. Zones with entry delay are the 
exit/entry zone and active zone.

Exit Delay:

 A period for user to leave detecting area once the system armed. Zones with exit delay will 

not alarm during this period. The zones with exit delay are the exit/entry zone and the active zone.

Supplementary  Entry  Delay: 

The  Supplementary  Entry  Delay  is  a  pre-alarm  feature  that  is 

employed in the event that the system is not disarmed during the entry delay.

Panel ID:

 

ID

 

address

 

can

 

be

 

set

 

for

 

each

 

control

 

panel

 

so

 

that

 

the

 

CMS

 

can

 

identify

Different

 

ID

 

must

 

be

 

set

 

for

 

different

 

control

 

panels

which

 

is

 4-8 

digits

 

utmost

 

with

 

default

 

as

 1234.

Duress Code:

 

When

 

user

 

is

 

forced

 

to

 

disarm

 

the

 

control

 

panel

 

by

 

burglar

user

 

inputs

 

duress

 

password

the

 

control

 

panel

 

is

 

disarmed

 

but

 

sends

 

alarm

 

information

 

to

 

the

 

center

 

stations

 

or

 

receiver

The

 

duress

 

password

 

can

 

be

 

used

 

to

 

disarm

 

but

 

set

 

parameters

.

Chime

 

Zone

:

 During disarm, while the zone is triggered, the panel will sound 

   

 

alarm

 

system!

A  facility  that  detects  intrusion  and  abnormal  state  automatically  via  some  electric  or 

Welcome to intelligent

 

zones. Other zones are still in arm status.

Appendix 4: Ter m Definitions

Summary of Contents for LHD8003

Page 1: ...86 755 33265388 Website http www csst longhorn com E mail helen p csst com TH ST TH THE 4 BUILDING 1 FLOOR OF THE 5 BUILDING NEW AND HIGH TECHNOLOGY PARK GUANGMING WANDAIHENG BAOAN SHENZHEN CHINA LHD...

Page 2: ...CREATING SECURITY SOLUTION...

Page 3: ...Address CMS 2 Phone NO SMS Center 1 SMS Center 1 Address SMS Center 1 Phone NO SMS Center 2 SMS Center 2 Address SMS Center 2 Phone NO 02 PACKING LIST Note It should include screws 4pcs EOL resistanc...

Page 4: ...1 2 Arm Stay 5 5 6 6 7 7 8 8 8 9 9 10 10 12 13 13 13 14 14 15 15 15 15 16 18 19 19 20 21 22 22 22 23 23 23 24 7 1 3 Disarm 7 2 Arm Disarm via Phone 7 3 Arm Disarm via SMS 7 4 Trigger Alarm via Keypad...

Page 5: ...lay intelligent voice guide operation Periodic supervision for wireless PIR and magnetic switch PSTN or GSM dialing or SMS message send for alarm optional Upload and download function optional 255 eve...

Page 6: ...ng guidelines 1 Whenever possible mount the panel centrally in relation to wireless sensors 2 Avoid installation in close proximity to sources of high noise or radio frequency interference for example...

Page 7: ...wireless detector magnetic switch siren and keyfobs etc Step 6 Test the communication signal of chosen mounting location Step 7 Permanently install the control panel and transmitters Figure 5 TX TX R...

Page 8: ...adaptor and plug the backup battery The control panel can not be initialized by only battery Parameters of power adaptor Input 100V 240VAC 50 60HZ 0 5A Output 12VDC 1 5A Backup battery 7 2V 1800mAh Ni...

Page 9: ...ct attention to the depth of screws to make sure easy hang and tamper switch work normally There are 2 tamper switches front tamper and rear tamper Compress the tamper switch while installing If the c...

Page 10: ...g symbols or marks Selected for multiple choice Unselected for multiple choice Selected for single choice Unselected for single choice Counting down System trouble Display of alarm events Alarm List S...

Page 11: ...ent alarm way 1 For entry exit zone only during arm away and arm stay will the zone be triggered with alarm delay 2 For active zone only during arm away will the zone be triggered with alarm delay 3 W...

Page 12: ...will auto release the code While if the code is locked after alarm auto release must be available after system re intialization or within 30 minutes If the code is input wrong the voice will guide Wr...

Page 13: ...alance for SIM card Commu nication Trouble Trouble There are 8 types of zones entry exit zone active zone perimeter zone panic zone fire zone gas zone tamper zone and duress zone There are 22 zones zo...

Page 14: ...ng Arm or disarm is not available during programming or trouble query Via keypad requires installer code while via keypad requires no code Exit Delaying s When the exit delay ends the voice guide will...

Page 15: ...isarmed alarm log eliminated 2 Disarm with alarm status saved Input the code except installer code ending with just the arm LED turns from Red to Green with voice guide Disarmed Disarm 2 0 1 2 2 0 1 0...

Page 16: ...r confirm Press to quit programming to previous menu Or it will return to previous automatically with no operation within 1 minute 27 28 Through this operation all communication buffers are cleared an...

Page 17: ...confirm or press to quit To set duress code 1 From the menu select Code Set Duress Code Duress Code Set While you disarm with duress code it will indicate Disarm on site but will dial or send alarm in...

Page 18: ...digits utmost Press to finish Or if no figure is input and is pressed directly the number will be deleted Voice Phone Interface Set It enables you to select PSTN or GSM as dialling way To set voice ph...

Page 19: ...n finished Siren test is strongly recommended periodically for safety which includes wired siren wireless siren and built in siren To test siren 1 From the menu select Service 2 Press the navigation k...

Page 20: ...it is registered the info will display on LCD If it isn t registered it will indicate as unknown signal 4 Press to quit after test finish GSM Test To ensure the validity of GSM communication please te...

Page 21: ...21 22 wired zones Zones No 17 and 19 To set siren function 1 From the main menu select Programming Device Zone Zone Siren Set 2 Use the navigation key to select the zone ending with 3 Then use naviga...

Page 22: ...nt If the function of Send for service is closed the trouble info will not be sent during enter ir quit programming or zone bypass It will send all event as default 39 40 To send for alarm 1 From the...

Page 23: ...ttempts option determines the number of times the system tries to call a telephone number before moving on to the next number in sequence It will not dial again if it exceeds the attempts Comm To set...

Page 24: ...tion Exit Delay S System 2 Press to edit with icon indication 3 Set the exit delay 0 300s 4 Press to finish and to exit Supplementary Entry Delay The Supplementary Entry Delay is a pre alarm feature t...

Page 25: ...While before the message is sent to the station and the telephone line recovers connected well the message will be cancelled Or if the message for Line loss is sent to the station successfully before...

Page 26: ...rm stay press 2 for disarm press 3 For alarm press 5 Turn on site siren press 6 turn off site siren press 7 for hang up please press 0 repeat Chapter 9 Telecontrol via Phone or SMS Pressing any key du...

Page 27: ...to the set phone number or SMS center for alarm or system trouble through Contact ID For example the control panel ID is 1234 when fire alarm disarm or zone trouble occurs it will send SMS as followi...

Page 28: ...et the incorrect telephone number User telephone is busy during alarm Few ringing attempts lead the system to hang up the phone automatically Battery is drained Enroll remote controller without progra...

Page 29: ...tenance may lead to the system disable Weekly testing is necessary to ensure the system work normally Chapter 12 Warranty and Limitations 53 54 Appendix 1 System Default Parameters No Setting Item Par...

Page 30: ...Ent Delay Output Trigger PGM Cut off Clear Users Del Superv SV CMS SMS Zone Trb Ind Call Back Reg Dis En Ex Per Line Loss TX Interface Auto ON OFF Wired Test WL Test Built in Test Clear WL Clear Sing...

Page 31: ...Zone 1 WL Register 1 By Code Learn 2 By Code Input 2 Clear WL 1 Clear Single 2 Clear All 3 Set zone Type 5 Chime Zone Set 4 Zone Siren Set 2 Keyfobs 1 Keyfob Register 1 By Code Learn 2 By Code Input...

Page 32: ...e entry exit zones active zones perimeter 24 hour zone No matter armed or disarmed it is in valid detecting status It is usually used in fire alarm duress alarm and other emergent alarm which can be c...

Page 33: ...Appendix 5 Zone Type Setting Figure Zone NO Installation Position Type Bypass or not 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 61...