LONGHORN LHD8003 Installation Manual Download Page 26

Clear Users

Clear  User  Codes  deletes  all  programmed  user  codes  and  restores  the  default  master  and  installer 
codes and duress codes.
To clear users:

1.  From the main menu, select 

Programming

 “#”

Initialization

” 

#

 “

Clear Users

”  “#”.

2.  It will display on LCD 

Clear users?

”, 

press

 “#” 

to

 

confirm

or

 “*” 

to

 

exit

.

Clear Users by Hardware

Clear

ing

  user  codes  can  be  also  realized  by  hardware  jumper.  There  is  a  jumper  on  the  control  panel 

board 

J3

”(

See

 

Figure

 1-

Main

 

Board

 

Schematic

). 

If

 

user

 

codes

 

are

 

forgotten

pls

 

power

 

off

and

 

put

 

the

 

jumper

 

to

  “

Default

”  

and

 

then

 

restart

 

the

 

system

which

 

will

 

reset

 

user

 

codes

 

as

 

default

The

  “

Default

”  

jumper

 

should

 

be

 

cut

-

off

 

after

 

the

 

system

 

initialization

or  else,  the  action  will  repeat  next  power-on.

Reset Zones

This function resets all wireless zones into panic and all wired zones into entry/exit zones.
To reset zones:

1.    From  the  main  menu,  select 

Programming

  “ #”

Initialization

”  

  “

Reset    Zone  Type

”  

.

2.  It will display on LCD 

Reset Zone Type?

”, 

press

 “#” 

to

 

confirm

 

or

 “

*

” 

to

 

exit

.

  “ #”

  “ #”

Clear Wireless

Clear all wireless includes wireless zones, keyfobs and sirens.

To clear wireless:

1.  From the main menu, select “Programming”→“

#

”→“Initialization”→“

#

”→“Clear Wireless”

 

.

2.  It will display on LCD “Clear Wireless?”

press

 

#

 

to

 

confirm

 

or

 

*

 

to

 

exit

.

 “#”

6  telephone  number  and  6  SMS  phone  number  can  be  set  in  this  system.  Regarding  telephones,   

number 1 and 2 means for CMS and 3-6 means for common phone numbers.

9.1 Telecontrol via Phone

It enables you to remote program the control panel via telephone, such as arm-away, arm-stay, disarm, 

repeat alarm voice, and active or mute site siren, etc. You can call the phone number set in the control 

panel. After call attempts set, it will hang off with voice guide to input password ending with 

“#”: “

For 

arm-  away,  press  1,  for  arm-stay,  press  2,  for  disarm,  press  3,  For  alarm 

,  press  5, Turn-on  site 

siren, press 6, turn-off site siren, press 7, for hang up, please press 0

”. 

repeat

Chapter 9: Telecontrol via Phone or SMS

Pressing any key 

 during voice play may cause communication error. It 

is suggest to operate after voice. If the system is under programming, remote programming is not 

available. There should be no voice indication during remote program. 

on control panel or phone

Note 

-47- 

-48-  

9.2 Dial to Alar m via Panel 

The control panel will call the set phone numbers during alarm. You will hear the voice around 5s after pick-

up and will repeat after another 5s, which will last 5 times and then hangs up automatically. After  hang up, 

if no voice guide, or user can not wait, you can press 

5

”, 

then

 

the

 

panel

 

will

 

issue

 

alarm

 

indication

.

 

Before it hangs up, you can program by phone.

See following:

Disarm:   press 

3

”.

Arm-away:   press 

3

” 

to

 

disarm

 

and

 

then

 “

1

” 

to

 

arm

 

away

.

Arm-stay:   press 

3

” 

to

 

disarm

 

and

 

then

 “

2

” 

to

 

arm

 

stay

.

Repeat alarm:   press 

5

” 

to

 

repeat

 

the

 

alarm

.  

Note

Alarm is not available to repeat after disarm.

Pressing any key on control panel or phone during voice play may cause communication error. It is 

suggest  to  operate  after  voice.  If  the  system  is  under  programming,  remote  programming  is  not 

available. There should be no voice indication during remote program. 

Note 

Turn off siren:   press 

7

”.

Turn on siren:   press 

6

,on-site siren will turn off after 10s

.

Hang up:   press 

0

” 

to

 

hang

 

up

 

directly

 

and

 

the

 

system

 

will

 

not

 

dial

 

any

 

phone

 

number

Note 

9.3 Telecontrol via SMS

It enables you to arm, disarm or query status via SMS. For example, user code is 0808, and control panel 
ID is 1234, operate as following:

If program is successful, it means arm or disarm success

While

 

program

 

fails

,

means

 

arm

 

or

 

disarm

 

failure

.

 Arm

 

or  disarm

 

can

 

not

 

be

 

available

 

during

 

programming.  With

 

zone

 

alarm

arm

 

can

 

not

 

be

 

realized. There must be no space before or between SMS words.

it 

Summary of Contents for LHD8003

Page 1: ...86 755 33265388 Website http www csst longhorn com E mail helen p csst com TH ST TH THE 4 BUILDING 1 FLOOR OF THE 5 BUILDING NEW AND HIGH TECHNOLOGY PARK GUANGMING WANDAIHENG BAOAN SHENZHEN CHINA LHD...

Page 2: ...CREATING SECURITY SOLUTION...

Page 3: ...Address CMS 2 Phone NO SMS Center 1 SMS Center 1 Address SMS Center 1 Phone NO SMS Center 2 SMS Center 2 Address SMS Center 2 Phone NO 02 PACKING LIST Note It should include screws 4pcs EOL resistanc...

Page 4: ...1 2 Arm Stay 5 5 6 6 7 7 8 8 8 9 9 10 10 12 13 13 13 14 14 15 15 15 15 16 18 19 19 20 21 22 22 22 23 23 23 24 7 1 3 Disarm 7 2 Arm Disarm via Phone 7 3 Arm Disarm via SMS 7 4 Trigger Alarm via Keypad...

Page 5: ...lay intelligent voice guide operation Periodic supervision for wireless PIR and magnetic switch PSTN or GSM dialing or SMS message send for alarm optional Upload and download function optional 255 eve...

Page 6: ...ng guidelines 1 Whenever possible mount the panel centrally in relation to wireless sensors 2 Avoid installation in close proximity to sources of high noise or radio frequency interference for example...

Page 7: ...wireless detector magnetic switch siren and keyfobs etc Step 6 Test the communication signal of chosen mounting location Step 7 Permanently install the control panel and transmitters Figure 5 TX TX R...

Page 8: ...adaptor and plug the backup battery The control panel can not be initialized by only battery Parameters of power adaptor Input 100V 240VAC 50 60HZ 0 5A Output 12VDC 1 5A Backup battery 7 2V 1800mAh Ni...

Page 9: ...ct attention to the depth of screws to make sure easy hang and tamper switch work normally There are 2 tamper switches front tamper and rear tamper Compress the tamper switch while installing If the c...

Page 10: ...g symbols or marks Selected for multiple choice Unselected for multiple choice Selected for single choice Unselected for single choice Counting down System trouble Display of alarm events Alarm List S...

Page 11: ...ent alarm way 1 For entry exit zone only during arm away and arm stay will the zone be triggered with alarm delay 2 For active zone only during arm away will the zone be triggered with alarm delay 3 W...

Page 12: ...will auto release the code While if the code is locked after alarm auto release must be available after system re intialization or within 30 minutes If the code is input wrong the voice will guide Wr...

Page 13: ...alance for SIM card Commu nication Trouble Trouble There are 8 types of zones entry exit zone active zone perimeter zone panic zone fire zone gas zone tamper zone and duress zone There are 22 zones zo...

Page 14: ...ng Arm or disarm is not available during programming or trouble query Via keypad requires installer code while via keypad requires no code Exit Delaying s When the exit delay ends the voice guide will...

Page 15: ...isarmed alarm log eliminated 2 Disarm with alarm status saved Input the code except installer code ending with just the arm LED turns from Red to Green with voice guide Disarmed Disarm 2 0 1 2 2 0 1 0...

Page 16: ...r confirm Press to quit programming to previous menu Or it will return to previous automatically with no operation within 1 minute 27 28 Through this operation all communication buffers are cleared an...

Page 17: ...confirm or press to quit To set duress code 1 From the menu select Code Set Duress Code Duress Code Set While you disarm with duress code it will indicate Disarm on site but will dial or send alarm in...

Page 18: ...digits utmost Press to finish Or if no figure is input and is pressed directly the number will be deleted Voice Phone Interface Set It enables you to select PSTN or GSM as dialling way To set voice ph...

Page 19: ...n finished Siren test is strongly recommended periodically for safety which includes wired siren wireless siren and built in siren To test siren 1 From the menu select Service 2 Press the navigation k...

Page 20: ...it is registered the info will display on LCD If it isn t registered it will indicate as unknown signal 4 Press to quit after test finish GSM Test To ensure the validity of GSM communication please te...

Page 21: ...21 22 wired zones Zones No 17 and 19 To set siren function 1 From the main menu select Programming Device Zone Zone Siren Set 2 Use the navigation key to select the zone ending with 3 Then use naviga...

Page 22: ...nt If the function of Send for service is closed the trouble info will not be sent during enter ir quit programming or zone bypass It will send all event as default 39 40 To send for alarm 1 From the...

Page 23: ...ttempts option determines the number of times the system tries to call a telephone number before moving on to the next number in sequence It will not dial again if it exceeds the attempts Comm To set...

Page 24: ...tion Exit Delay S System 2 Press to edit with icon indication 3 Set the exit delay 0 300s 4 Press to finish and to exit Supplementary Entry Delay The Supplementary Entry Delay is a pre alarm feature t...

Page 25: ...While before the message is sent to the station and the telephone line recovers connected well the message will be cancelled Or if the message for Line loss is sent to the station successfully before...

Page 26: ...rm stay press 2 for disarm press 3 For alarm press 5 Turn on site siren press 6 turn off site siren press 7 for hang up please press 0 repeat Chapter 9 Telecontrol via Phone or SMS Pressing any key du...

Page 27: ...to the set phone number or SMS center for alarm or system trouble through Contact ID For example the control panel ID is 1234 when fire alarm disarm or zone trouble occurs it will send SMS as followi...

Page 28: ...et the incorrect telephone number User telephone is busy during alarm Few ringing attempts lead the system to hang up the phone automatically Battery is drained Enroll remote controller without progra...

Page 29: ...tenance may lead to the system disable Weekly testing is necessary to ensure the system work normally Chapter 12 Warranty and Limitations 53 54 Appendix 1 System Default Parameters No Setting Item Par...

Page 30: ...Ent Delay Output Trigger PGM Cut off Clear Users Del Superv SV CMS SMS Zone Trb Ind Call Back Reg Dis En Ex Per Line Loss TX Interface Auto ON OFF Wired Test WL Test Built in Test Clear WL Clear Sing...

Page 31: ...Zone 1 WL Register 1 By Code Learn 2 By Code Input 2 Clear WL 1 Clear Single 2 Clear All 3 Set zone Type 5 Chime Zone Set 4 Zone Siren Set 2 Keyfobs 1 Keyfob Register 1 By Code Learn 2 By Code Input...

Page 32: ...e entry exit zones active zones perimeter 24 hour zone No matter armed or disarmed it is in valid detecting status It is usually used in fire alarm duress alarm and other emergent alarm which can be c...

Page 33: ...Appendix 5 Zone Type Setting Figure Zone NO Installation Position Type Bypass or not 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 61...

Reviews: