Dial Back
RP dial back is a security feature that helps ensure that remote programming is only performed by
authorized personnel. When the Remote Programmer contacts the panel, the panel hangs up and calls the
Callback telephone number.
To set RP call back:
1. From the main menu, select
“
Programming”
→
“#”
→
“
Comm
.
”
→
“#”
→
“
Remote Program”
→
“#”
→
“
Dial Back
”
→
“#”
, Input utmost 16 digits.
2. Press
“#”
for
confirm
.
Note
RP
Password
The RP pass
is a 6-digit code that grants access to remote programming. When establishing an RP
connection, the pass
programmed in the RP customer file on the PC must be identical to the system
’
s
RP pass
.
To set RP pass
:
1. From the main menu, select
“
Programming”
→
“#”
→
“
Comm
.
”
→
“#”
→
“
Remote Program”
→
“#”
→
“
RP password”
→
“#”.
2.Input 6 figures.
3.Press
“#”
for
confirm.
RP Permission
Options are available to enable, disable or limit access to remote programming.
To set RP access options:
1. From the main menu, select
“
Programming”
→
“#“
→
“
Comm
.
”
→
“#”
→
“
Remote Program”
→
“#”
→
“
Permission”
→
“#”.
2. Select the access options.
8.3.8.3
System
Option
Entry Delay
Entry delay means a period for user to enter detection area, activate the delay zone and disarm before
the system alarms.
To set entry delay:
1. From the main menu, select
“
Programming”→
“ #”
→
“
System Option”→
“ #”
→
“
Entry Delay(S)
”
“ #” .
2. Press
“#”
to
edit
with
icon
indication
.
3. Set the entry delay(0-300s).
4. Press
“#”
to
finish
and
“
*
”
to
exit
.
Exit Delay
A period for user to leave detecting area once the system armed. Zones with exit delay will not alarm
during this period.
word
word
word
word
→
To set exit delay:
→
→
“
→
1. From the main menu, select
“
Programming”→
#”
→
Option”→
#”
→ Exit Delay(S)
”
“ #” .
“
“
System
“
“
2. Press
“#”
to
edit
with
icon
indication
.
3. Set the exit delay(0-300s).
4. Press
“#”
to
finish
and
“
*
”
to
exit
.
Supplementary Entry Delay
The Supplementary Entry Delay is a pre-alarm feature that is employed in the event that
the system is not disarmed during the entry delay. And the period is set as 5s. While this function is turned
off, the system will alarm immediately after entry delay.
To set supplementary entry delay:
1. From the main menu, select
“
Programming”→
“#”
→
“
System Option”→
“#”
→
“
Supp. Ent. Delay
”
“#” .
2. From the navigation key to select
“
ON
”
or
“
OFF
”
and
confirm
with
“#”.
3. Press
“
*
”
to
exit
.
PGM Option
The PGM is a programmable output that is triggered according to specific system status conditions.
The
output trigger option determines the conditions that activate and disactivate the PGM output.
To trigger PGM output:
1. From the main menu, select
“
Programming
”
→
“ #”
→
“
System Option
”
→
“ #”
→
“
PGM
”
→
“ #”
→
Output
Trigger
”
“#”.
2. Press the navigation key to select one of output trigger and press
“
*
”
to
exit
.
-43-
-44-
PGM Trigger
Not used
Zone 1 Alarm
Zone 2 Alarm
Zone 3 Alarm
Zone 4 Alarm
Zone 5 Alarm
Zone 6 Alarm
Zone 7 Alarm
Zone 8 Alarm
Zone 9 Alarm
Zone 10 Alarm
Zone 11 Alarm
Zone 12 Alarm
Zone 13 Alarm
Zone 14 Alarm
Zone 15 Alarm
See following table:
Activated by……
Disactivated……
Instant Trigger
for PGM
Null
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
See above
Disarm or PGM cut-off
If no phone number is set or edit for call back, RP call back doesn
’
t work. It is set as direct
dialing as default.