18

5831 Series

 Installation and Operating Instructions

Setting Descriptions 

Opening Time:

 

Following an activation signal, door moves from fully 

closed to open check or 80°, whichever occurs first, 

according to Table 1 . 

NOTE:

 Operator calculates time during Auto Setup . 

Hold Open Time:

 

Hold open time is delay in open position before door 

starts to close . Hold Open is adjustable from 1 - 30 

seconds . ANSI 156 .19 requires a door to hold open 

for a minimum of 5 seconds (default from factory) .

Closing Time:

 

Following Hold Open time, door moves from fully 

open to close check or 10°, whichever occurs first, 

according to Table 1 . 

NOTE:

 Operator calculates time during Auto Setup .

Close Check:

 

Close Check brings door to latch point without 

slamming door .  It occurs in last 10° of closing and 

shall not be less than 1 .5 seconds .

Closing Force:

 

Door shall not close with a force greater than 6 .8 kg 

when measured at latch side of closing stile . Closing 

force is adjustable to 3 .6 kg .

Open and Power Close Force: 

Open and Power Close Force adjusts force operator 

will apply in open direction . If optional Power 

Close feature is turned on, Power Close Force will 

be adjustable using this setting . Operator shall be 

adjusted so that a stopped door will apply a force in 

opening direction of 6 .8 kg or less . If optional Power 

Close feature is enabled, door shall be adjusted so 

that a stopped door will apply a force of less than 6 .8 

kg in closing direction .

Option Features:

 

•  Power Close: Operator will apply a small amount 

of power if door did not close in expected close 

time to assist in closing door . Power Close will 

activate and turn off when door is fully closed or 

if door does not move after attempting to close 

for two (2) seconds . 

•  Push and Go: Operator will initiate an automatic 

open cycle when door is manually moved in 

open direction . 

•  Dynamic Braking: Operator will brake door if 

excessive door speed (4 times programmed 

Open Time) occurs . For example, from a wind 

load or an abusive open condition . 

•  Latch Assist: Operator will apply a force in close 

direction for 1/2 second when operator receives 

an activation signal to assist an electric strike in 

unlocking . When door closes, operator will apply 

a force in close direction to assist in latching 

door .

Executive Mode:

 

When Executive mode is activated, operator will 

open door when it receives an activation signal and 

door will remain open until a second activation 

signal is received .

NOTE:

 Power Close, Push and Go, Latch Assist, and 

Executive Mode must only be enabled when unit is 

powered using optional 24VDC power supply .

Table 1: Door Open and Close Time in Seconds

Door 

Weight 

(kg)

Door Width (mm)

915

960

1015

1060

1120

1220

23

3 .0

3 .0

3 .0

3 .0

3 .0

3 .0

34

3 .0

3 .0

3 .0

3 .0

3 .0

3 .1

45

3 .0

3 .0

3 .0

3 .2

3 .3

3 .6

68

3 .3

3 .5

3 .7

3 .9

4 .1

4 .4

90

3 .8

4 .0

4 .3

4 .5

4 .7

5 .1

115

4 .3

4 .5

4 .8

5 .0

5 .2

5 .7

Summary of Contents for ASSA ABLOY 5831 Series

Page 1: ...mm x4 Wood 12 x 32mm x10 Aluminum Hollow Metal 1 4 20 x 19mm x10 Hex Wrench Through Bolt 1 4 20 x 41mm x4 Arm Spacer x2 Rivetnut Installation Tool Mounting Post x2 Washer x12 9 64 3 16 Push Side Paral...

Page 2: ...njury Coin Battery Safety Information WARNING KEEP BATTERIES OUT OF REACH OF CHILDREN If the battery is a lithium button coin battery placing the battery in any part of the body or swallowing may lead...

Page 3: ...not problematic provided that level of automatic use is not sustained If the door is operated by wireless RF transmitter pushbutton more often than described in the 80 25 rule the door closing cycle w...

Page 4: ...general public limits Battery Safety Information Risk of explosion and personal injury if device is installed into non compatible circuit Do not open mutilate or expose to conducting materials metal...

Page 5: ...230VAC grounded power outlet is available in vicinity of door Set up a protective barrier caution warning tape to prevent unauthorized access to work area If applicable remove existing door closer Ma...

Page 6: ...stop Figure 5 This line is shown on template PUSH SIDE Operator and Arm Installation Figure 5 Prepare Door and Frame Figure 4 16mm Minimum 38mm Maximum Greater than 38mm 38mm Or Less 16mm Minimum 38m...

Page 7: ...ceiling covers face of frame Shoe should then be installed on underside of frame header NOTE If used triangular support bracket face must be flush against face of frame header or frame rabbet Dependin...

Page 8: ...bracket holes b Using provided rivnut installation tool install bracket to door with minimum four 4 20 steel rivnuts DO NOT TIGHTEN If door is wood or hollow metal a Use 3 8 bit to drill operator mou...

Page 9: ...ket using a large adjustable wrench Figure 12 Narrow Stile Door Use lower threaded holes in mounting bracket Wide or Medium Stile Door Use upper threaded holes in mounting bracket 2 Install operator m...

Page 10: ...r and Arm Installation Preload Arm 1 Pull arm elbow 6mm away from face of door to add tension Figure 15 2 While maintaining arm elbow position at 6mm increase or decrease arm length by twisting end li...

Page 11: ...cations with a center punch and hammer CAUTION On an aluminum storefront door operator mounting holes must not be drilled into top rail web rail to stile tie rod s or rail to stile junction CAUTION To...

Page 12: ...four 4 20 socket head cap screws and washers DO NOT TIGHTEN NOTE For light duty or hollow core doors with insufficient top rail blocking supplied through bolts or sex nut and bolts are required 2 Usi...

Page 13: ...ivot bracket hole 3 With arm coupling bolts facing up and end link hole aligned with arm pivot bracket hole place larger end of arm onto pinion shaft Figure 26 4 While maintaining arm position tighten...

Page 14: ...Battery Pack Press and hold 3 Position switch in OPTION position Green LED fully charged Yellow LED partially drained Red LED fully drained operator will not function in automatic mode NOTE Battery c...

Page 15: ...ton are mounted between 86 4cm minimum and 121 9cm maximum from floor Reference conformance to requirements set out in AS1428 1 and other applicable building codes for additional information regarding...

Page 16: ...hen Power Close and or Push and Go features are enabled 1 Route power supply wiring to a 230VAC outlet DO NOT plug power supply into outlet until all connections are made 2 Route wires through end lin...

Page 17: ...n Operator will store settings and exit programming mode NOTE Refer to Customising Settings beginning on page 19 to adjust settings or enable optional features To reset controller Press and hold ENTER...

Page 18: ...at a stopped door will apply a force in opening direction of 6 8 kg or less If optional Power Close feature is enabled door shall be adjusted so that a stopped door will apply a force of less than 6 8...

Page 19: ...ss and release ENTER button to store value 5 Press and hold ENTER button for three 3 seconds to exit programming mode NOTE LEDs will indicate minimum and maximum values as adjustments are made Green i...

Page 20: ...ON Red LED indicates feature is OFF 3 Rotate thumb wheel to turn feature on or off 4 Press and release ENTER button to store setting 5 Press and hold ENTER button for three 3 seconds to exit programm...

Page 21: ...e 14 and ensure battery is properly connected to operator Refer to Linking Wireless Pushbuttons page 17 and program RF pushbutton Refer to Programming Operator page 17 and program operator To verify a...

Page 22: ...Force Can t Remove Battery From Housing Refer to Figure 13 or Figure 27 and note T shaped channel at top of battery housing Insert a small flat head screwdriver into slot above T channel and gently p...

Page 23: ...sion shown to 165mm Door Stays Open at 90 Degrees Only When Power Operated Refer to Programming Operator page 17 and Auto Set operator When Used Manually Arm Reverses and Does Not Allow Door to Close...

Page 24: ...d Oakleigh Victoria 3166 Australia info au assaabloy com assaabloyopeningsolutions com au Copyright 2021 ASSA ABLOY Australia Pty Limited All rights reserved Reproduction in whole or in part without t...

Reviews: