background image

19

5831 Series

 Installation and Operating Instructions

Copyright © 2021, ASSA ABLOY Australia Pty Limited. All rights reserved. Reproduction in whole or

in part without the express written permission of ASSA ABLOY Australia Pty Limited is prohibited.

700002AU  Rev 2  06/21

Customising Settings (Optional)

Open/Close Time, Open and Power Close Force, 

and Hold Open Time are preset to comply with 

ANSI standards for low-energy operators but may 

be adjusted if approved by the Authority Having 

Jurisdiction (AHJ) .

Before attempting any changes to these settings, 

make sure Auto Setup process has been successfully 

completed .  

1 .  Enter programming mode .  

Press and hold both “SELECT” and “ENTER” 

buttons until LEDs 1 - 4 flash green 

(approximately 3 seconds) . 

•  Open & Close Time LED will light

2 .  Press and release “SELECT” button to choose 

setting to be modified .

3 .  With desired LED lit, rotate thumb wheel to 

adjust setting . See Table 2 . 

4 .  Press and release “ENTER” button to store value .

5 .  Press and hold “ENTER” button for three (3) 

seconds to exit programming mode .  

NOTE:

 

•  LEDs will indicate minimum and maximum 

values as adjustments are made . Green 

indications are within ANSI standards . Red 

indications exceed ANSI standards .  

•  Pattern of LEDs 1-4 will indicate previously set 

value until thumb wheel is rotated . 

 

•  Verify adjustments using a stop watch and force 

gauge .  

Table 2: Time and Force Settings

LED

OPEN FORCE

POWER CLOSE FORCE

Set-

tings

1

2

3

4

Open/ 

Close 

Time

Hold 

Open 

Time

915mm 

Door 

Force

1060mm 

Door 

Force

1220mm 

Door 

Force

915mm 

Door 

Force

1060mm 

Door 

Force

1220mm 

Door 

Force

1

GRN

OFF

OFF

OFF

2 .5

1

7

6

5

14

12

10

2

OFF

GRN

OFF

OFF

3 .5

2

9

8

7

14

12

10

3

OFF

OFF

GRN

OFF

4

3

12

10

9

15

13

11

4

OFF

OFF

OFF

GRN

4 .5

5

15

13

11

16

14

12

5

GRN GRN

OFF

OFF

5

7

17

15

13

18

15

13

6

GRN

OFF

GRN

OFF

6

10

19

16

14

19

16

14

7

GRN

OFF

OFF

GRN

7

15

21

18

16

20

17

15

8

GRN GRN GRN

OFF

7 .5

20

23

20

17

21

18

16

9

GRN GRN

OFF

GRN

8

25

25

21

19

23

20

17

10

GRN GRN GRN GRN

9

30

30

26

22

25

21

19

11

RED

RED

RED

RED

N/A

Exec-

utive 

Mode

N/A

N/A

N/A

N/A

N/A

N/A

Summary of Contents for ASSA ABLOY 5831 Series

Page 1: ...mm x4 Wood 12 x 32mm x10 Aluminum Hollow Metal 1 4 20 x 19mm x10 Hex Wrench Through Bolt 1 4 20 x 41mm x4 Arm Spacer x2 Rivetnut Installation Tool Mounting Post x2 Washer x12 9 64 3 16 Push Side Paral...

Page 2: ...njury Coin Battery Safety Information WARNING KEEP BATTERIES OUT OF REACH OF CHILDREN If the battery is a lithium button coin battery placing the battery in any part of the body or swallowing may lead...

Page 3: ...not problematic provided that level of automatic use is not sustained If the door is operated by wireless RF transmitter pushbutton more often than described in the 80 25 rule the door closing cycle w...

Page 4: ...general public limits Battery Safety Information Risk of explosion and personal injury if device is installed into non compatible circuit Do not open mutilate or expose to conducting materials metal...

Page 5: ...230VAC grounded power outlet is available in vicinity of door Set up a protective barrier caution warning tape to prevent unauthorized access to work area If applicable remove existing door closer Ma...

Page 6: ...stop Figure 5 This line is shown on template PUSH SIDE Operator and Arm Installation Figure 5 Prepare Door and Frame Figure 4 16mm Minimum 38mm Maximum Greater than 38mm 38mm Or Less 16mm Minimum 38m...

Page 7: ...ceiling covers face of frame Shoe should then be installed on underside of frame header NOTE If used triangular support bracket face must be flush against face of frame header or frame rabbet Dependin...

Page 8: ...bracket holes b Using provided rivnut installation tool install bracket to door with minimum four 4 20 steel rivnuts DO NOT TIGHTEN If door is wood or hollow metal a Use 3 8 bit to drill operator mou...

Page 9: ...ket using a large adjustable wrench Figure 12 Narrow Stile Door Use lower threaded holes in mounting bracket Wide or Medium Stile Door Use upper threaded holes in mounting bracket 2 Install operator m...

Page 10: ...r and Arm Installation Preload Arm 1 Pull arm elbow 6mm away from face of door to add tension Figure 15 2 While maintaining arm elbow position at 6mm increase or decrease arm length by twisting end li...

Page 11: ...cations with a center punch and hammer CAUTION On an aluminum storefront door operator mounting holes must not be drilled into top rail web rail to stile tie rod s or rail to stile junction CAUTION To...

Page 12: ...four 4 20 socket head cap screws and washers DO NOT TIGHTEN NOTE For light duty or hollow core doors with insufficient top rail blocking supplied through bolts or sex nut and bolts are required 2 Usi...

Page 13: ...ivot bracket hole 3 With arm coupling bolts facing up and end link hole aligned with arm pivot bracket hole place larger end of arm onto pinion shaft Figure 26 4 While maintaining arm position tighten...

Page 14: ...Battery Pack Press and hold 3 Position switch in OPTION position Green LED fully charged Yellow LED partially drained Red LED fully drained operator will not function in automatic mode NOTE Battery c...

Page 15: ...ton are mounted between 86 4cm minimum and 121 9cm maximum from floor Reference conformance to requirements set out in AS1428 1 and other applicable building codes for additional information regarding...

Page 16: ...hen Power Close and or Push and Go features are enabled 1 Route power supply wiring to a 230VAC outlet DO NOT plug power supply into outlet until all connections are made 2 Route wires through end lin...

Page 17: ...n Operator will store settings and exit programming mode NOTE Refer to Customising Settings beginning on page 19 to adjust settings or enable optional features To reset controller Press and hold ENTER...

Page 18: ...at a stopped door will apply a force in opening direction of 6 8 kg or less If optional Power Close feature is enabled door shall be adjusted so that a stopped door will apply a force of less than 6 8...

Page 19: ...ss and release ENTER button to store value 5 Press and hold ENTER button for three 3 seconds to exit programming mode NOTE LEDs will indicate minimum and maximum values as adjustments are made Green i...

Page 20: ...ON Red LED indicates feature is OFF 3 Rotate thumb wheel to turn feature on or off 4 Press and release ENTER button to store setting 5 Press and hold ENTER button for three 3 seconds to exit programm...

Page 21: ...e 14 and ensure battery is properly connected to operator Refer to Linking Wireless Pushbuttons page 17 and program RF pushbutton Refer to Programming Operator page 17 and program operator To verify a...

Page 22: ...Force Can t Remove Battery From Housing Refer to Figure 13 or Figure 27 and note T shaped channel at top of battery housing Insert a small flat head screwdriver into slot above T channel and gently p...

Page 23: ...sion shown to 165mm Door Stays Open at 90 Degrees Only When Power Operated Refer to Programming Operator page 17 and Auto Set operator When Used Manually Arm Reverses and Does Not Allow Door to Close...

Page 24: ...d Oakleigh Victoria 3166 Australia info au assaabloy com assaabloyopeningsolutions com au Copyright 2021 ASSA ABLOY Australia Pty Limited All rights reserved Reproduction in whole or in part without t...