APPENDIX B - PARAMETERS BASED ON APPLICATION
Application
Parameter Code
DRV Group
When you want to change the frequency setting
DRV 00
When you want to change the acceleration and deceleration time of the motor
DRV 01, DRV 02
FUN Group
When you want to use the Jump Code
FUN 00
When you want to change the run/stop method
FUN 02
When you want to change the frequency reference source
FUN 01
When you want to prevent the motor from rotating at opposite directions
FUN 03
When you want to change the stopping method
FUN15
When DC injection braking is required before starting
FUN 33~36
When you want to set the maximum frequency and the base frequency according to the rated torque of the motor
FUN 37~40
When you want to adjust the starting frequency
FUN 06
When a large starting torque is needed for loads such as elevators (Manual/Auto Torque Boost)
FUN 09~10
When you want to select an appropriate output characteristic (V/F characteristic) according to loads
FUN 08
When you want to se up your own V/F pattern
FUN 16~19
When you want to use the energy saving function
FUN 14
When you want to protect the motor from overheating
FUN 51~54
When you want to output a signal when the overload condition lasts more than a fixed amount of time
FUN 47~48
When you want to cut off the output when the overload condition lasts more than a fixed amount of time
FUN 49~50
When you want to set the stall prevention function
FUN 45~46
When you want to prevent the resonance from the oscillating characteristics of a machine
FUN 28~31
When you want to start the inverter as soon as the power is turned ON
FUN 55
When you want to restart the inverter by resetting the fault when a fault occur
FUN 42~43
When you want to use the instant power failure restart function (Speed Search)
FUN 56~58
When you want to enter the motor constants
FUN 38~40
When you want to reduce noise or leakage current by changing the PWM carrier frequency
FUN 61
When you want to operate using PID feedback
FUN 62~72
When you want to copy the inverter parameter to another inverter
FUN 95~96
When you want to initialize the parameters
FUN 97
When you want to prevent the parameters from being changed
FUN 98
I/O Group
When you want to set the analog voltage or current for the frequency reference
I/O 34~37
When you want to set the step frequency
I/O 13~19
When you want to change the functions for the input terminals P1~P6
I/O 12 ~ 14
When you want to check the status of the input/output terminals
I/O 43~44
When you want to check the fault history of the inverter
I/O 46~47
When you want to use the JOG and multi step speed operation
I/O 01~06
When you want to change the 1
st
~ 7
th
acceleration/deceleration time
I/O 20~23
When you want to set the frequency detection level
I/O 39~40
When you want to change the functions of the multi function auxiliary contact output (AXA-AXC)
I/O 07~11
When you want to exchange the motor to commercial power line from inverter or the opposite
I/O 01~06
Summary of Contents for SV030iH-2U
Page 26: ...Chapter 2 Operation 24 Blank Page...
Page 34: ...Chapter 3 Quick Start Procedures 32 Blank Page...
Page 42: ...Chapter 4 Parameter List 40 Blank Page...
Page 66: ...Chapter 5 Parameter Description Function Group 64...
Page 67: ...Chapter 5 Parameter Description Function Group 65 Blank Page...
Page 81: ...Chapter 5 Parameter Description I O Group 79 Blank Page...