90
APPENDIX A - FUNCTIONS BASED ON USE
Set the function properly according to the load and operating conditions. Application and related functions are
listed in the following table.
Use
Related Parameter Code
Accel/Decel Time, Pattern Adjustment
DRV-01 [Acceleration Time], DRV-02 [Deceleration Time],
FUN 11 [Acceleration Pattern], FUN 12 [Deceleration Pattern]
Reverse Rotation Prevention
FUN 03 [Forward, Reverse Prevention]
Minimum Accel/Decel Time
FUN 11 [Acceleration Pattern], FUN 12 [Deceleration Pattern]
Accel/Decel at Continuous Rating Range
FUN 11 [Acceleration Pattern], FUN 12 [Deceleration Pattern]
Braking Operation Adjustment
FUN 15 [Stop Method], FUN 33~36 [DC Braking],
Operations for Frequencies Over 60 Hz
FUN 04 [Maximum Frequency],
FUN 25~26 [Frequency Limit]
Selecting an Appropriate Output
Characteristics for the Load
FUN 03 [Maximum Frequency],
FUN 05 [Base Frequency]
Motor Output Torque Adjustment
FUN 05 [Starting Frequency],
FUN 09~10 [Torque Boost],
FUN 45~46 [Stall Prevention],
FUN 39~40 [Rated Motor]
Output Frequency Limit
FUN 25~27 [Frequency Upper/Lower Limit],
I/O 20~24 [Analog Frequency Setting]
Motor Overheat Protection
FUN 51~53 [Electronic Thermal], FUN 38~40 [Rated Motor]
Multi Step Operation
I/O 01~06 [Define the Multi Function Input Terminals],
I/O 12~19 [Jog, Multi Step Frequency],
FUN 25~27 [Frequency Upper/Lower Limit]
Jog Operation
I/O 12 [Jog Frequency]
Frequency Jump Operation
FUN 28~32 [Frequency Jump]
Timing the Electronic Brake Operation
I/O 39~40 [Frequency Detection Level],
I/O 07~11 [Multi Function Output]
Displaying the Rotating Speed
DRV 04 [Motor Speed],
FUN 41~42 [Motor RPM Display Gain]
Function Alteration Prevention
FUN 98 [Parameter Lock]
Energy Saving
FUN 14 [Energy Saving]
Auto Restart Operation After Alarm Stop
FUN 42~43 [Auto Retry]
PID Feedback Operation
FUN 62~72 [PID Operation]
Frequency Reference Signal and Output
Adjusting
FUN 20~24 [Analog Frequency Setting]
Define the Multi-Function Input Terminals
I/O 01~06 [Define the Multi-Function Input Terminals]
Define the Multi-Function Input Terminals
I/O 07~11 [Multi Function Auxiliary Contact Output Setting]
Commercial Line
?
inverter Switchover
Operation
I/O 01~06 [Define the Multi-Function Input Terminals],
I/O 07~11 [Multi-Function Auxiliary Contact Output Setting]
Frequency Meter Calibration
I/O 34~37 [FM Output]
Operate by Communicating with a Computer
I/O 50 [Inverter No.],
I/O 51 [communication Speed]
I/O 52 [communication Timeout]
Summary of Contents for SV030iH-2U
Page 26: ...Chapter 2 Operation 24 Blank Page...
Page 34: ...Chapter 3 Quick Start Procedures 32 Blank Page...
Page 42: ...Chapter 4 Parameter List 40 Blank Page...
Page 66: ...Chapter 5 Parameter Description Function Group 64...
Page 67: ...Chapter 5 Parameter Description Function Group 65 Blank Page...
Page 81: ...Chapter 5 Parameter Description I O Group 79 Blank Page...