Chapter 5 - Parameter Description (I/O Group)
72
[OC1 Configured as ‘STALL’]
LV:
[Low voltage]
Whenever the inverter’s DC Link Voltage falls
below the under voltage of the drive, the inverter can
generate an output signal via the multi-function
output terminals.
[OC1 Configured as ‘LV’]
RUN:
[On Running]
Whenever the inverter is in the Run Mode, the
inverter can generate an output signal via the multi-
function input terminals.
[OC1 Configured as ‘RUN’]
COMM:
Whenever the inverter is in a Bypass Mode, the
inverter can generate an output signal via the multi-
function output terminals.
STEP_L, STEP_M, STEP_H:
The inverter can generate an output signal via the
multi-function output terminals for monitoring STEP
commands. The output signal is in binary format as
set by input terminals [I/O 01] through [I/O 06] via
the OC1, OC2 and OC3 terminals.
[OC1 Configured as ‘STEP_L’,
OC2 Configured as ‘STEP_M’,
OC3 Configured as ‘STEP_H’]
Output Current
Time
Time
FUN 46
[Stall level]
FUN 46
[Stall level]
OC1-EG
ON
OC1-EG
ON
DC Link Voltage
Time
Time
LV level (200V DC or 400V DC)
OC1-EG
ON
Output Frequency
Time
Time
OC1-EG
ON
ON
Output Frequency
Time
Time
OC2-EG
ON
ON
Time
OC3-EG
ON
Time
ON
ON
Speed
0
Speed
1
Speed
2
Speed
3
Speed
4
Speed
5
Speed
6
Speed
7
Jog
Summary of Contents for SV030iH-2U
Page 26: ...Chapter 2 Operation 24 Blank Page...
Page 34: ...Chapter 3 Quick Start Procedures 32 Blank Page...
Page 42: ...Chapter 4 Parameter List 40 Blank Page...
Page 66: ...Chapter 5 Parameter Description Function Group 64...
Page 67: ...Chapter 5 Parameter Description Function Group 65 Blank Page...
Page 81: ...Chapter 5 Parameter Description I O Group 79 Blank Page...