25
CHAPTER 3 - QUICK- START PROCEDURES
These Quick-Start Up instructions are for those applications where:
l
The user wants to get the iH inverter started quickly
l
The factory-preset values are suitable for the user application
The factory-preset values are shown on the ‘Chapter 4 - Parameter List’. The iH inverter is configured to
operate a motor at 60Hz (base frequency). If the application requires coordinated control with other controllers,
it is recommended the user become familiar with all parameters and features of the inverter before applying AC
power.
1.
Mounting the inverter (mount the inverter as described in ‘1.3 Mounting’)
l
Install in a clean, dry location
l
Allow a sufficient clearance around top and sides of inverter
l
The ambient temperature should not exceed 40°C (104°F)
l
If two or more inverters are installed in an enclosure, add additional cooling
2.
Wiring the inverter (connect wiring as described in ‘1.7 Power Terminals’)
l
AC power should be turned OFF
l
Verify the AC power matches the nameplate voltage