Chapter 5 - Parameter Description (Function Group)
47
[Auto Boost Pattern: ‘Torque Boost’]
FUN 11: Acceleration pattern
FUN 12: Deceleration pattern
FUN
¢º
Acc. pattern
11 Linear
FUN
¢º
Dec. pattern
12 Linear
Setting Range:
Linear, S-Curve, U-Curve
Factory Default:
Linear
[FUN 11] and [FUN 12] selects different
combinations of acceleration and deceleration
patterns.
Linear:
This is the general acceleration and
deceleration pattern for constant torque applications.
[Acc./Dec. Pattern: ‘Linear’]
S-Curve:
This pattern allows the motor to
accelerate and decelerat smoothly. At this time, the
actual acceleration and deceleration time are longer
about 10% than the acceleration and deceleration
time set in DRV 01-02.
[Acc./Dec. Pattern: ‘S-Curve’]
U-Curve:
This pattern provides more efficient
control of acceleration and deceleration in the
application like winding machines.
[Acc./Dec. Pattern: ‘U-Curve’]
FUN 13: Output Voltage Adjustment
FUN
¢º
Volt control
13 100 %
Setting Range:
40 to 110%
Factory Default:
100%
This function is used to adjust the output voltage of
the inverter. This is useful when using a motor with a
lower rated voltage than the main input voltage.
When this is set at 100%, the inverter outputs its
rated voltage.
[Output Voltage Adjustment]
Output Frequency
Time
Acc. Pattern
Dec. Pattern
Output Frequency
Time
Acc. Pattern
Dec. Pattern
Output Frequency
Time
Acc. Pattern
Dec. Pattern
Output Voltage
Output
Frequency
Freq. Base
100%
50%
When set at 50%
Summary of Contents for SV030iH-2U
Page 26: ...Chapter 2 Operation 24 Blank Page...
Page 34: ...Chapter 3 Quick Start Procedures 32 Blank Page...
Page 42: ...Chapter 4 Parameter List 40 Blank Page...
Page 66: ...Chapter 5 Parameter Description Function Group 64...
Page 67: ...Chapter 5 Parameter Description Function Group 65 Blank Page...
Page 81: ...Chapter 5 Parameter Description I O Group 79 Blank Page...