Chapter 3 – Quick-Start Procedures
26
3.1
Operation Using Keypad
1.
Apply AC power.
2.
If the message of DRV 00 is ‘Manual K/K’, go to step 11.
3.
Press the [PROG] key to display function group.
4.
Press the UP-arrow key to display FUN 01.
5.
Press the [PROG] key to enter into the program mode.
6.
Using arrow keys, select ‘Key”, then press the [ENTER] key.
7.
Press UP-arrow key to display FUN 02.
8.
Press [PROG] key to enter into the program mode.
9.
Using arrow keys, select ‘Key’, then press the [ENTER] key.
10.
Press the [MODE] key repeatedly until DRV 00 is displayed.
DRV
¢º
Manual K/K
00 FWD 0.00 Hz
MODE
FUN
¢º
Jump code
00 41
FUN
¢º
Freq. set
01 Terminal
PROG
FUN
¢º
Freq. set
01 Terminal
FUN
¢º
Freq. set
01 Key
FUN
¢º
Run/stop set
02 Terminal-1
PROG
FUN
¢º
Run/stop set
02 Terminal-1
FUN
¢º
Run/stop set
02 Key
ENTER
MODE
ENTER
DRV
¢º
Manual K/K
00 FWD 0.00 Hz