Device parameters and interfaces
Leuze
electronic
46
BPS 34
Leuze electronic
Notice!
Some controls make available a so-called "universal module". This module must
not
be ac-
tivated for the laser.
Attention!
The BPS 34 does not permanently store parameters changed via the PROFIBUS. Following
Power off/on, the currently configured parameters are downloaded from the PROFIBUS
manager. If no PROFIBUS manager is available following Power OFF/ON, the BPS 34 ac-
tivates its stored default settings.
8.1.5
Structure of the GSE modules
In the current version, a total of 27 modules are available for use. The modules may be
included into the project according to requirements and application.
The modules fall into the following categories:
• Parameter module for the configuration of the BPS 34.
• Status or control modules that influence the input/output data.
• Modules that may include both parameters and control or status information.
Notice!
All
input and output modules
described in this documentation are described
from the
controller's perspective
.
Described inputs (I) are inputs in the control.
Described outputs (O) are outputs in the control.
Described parameters (P) are parameters of the GSE file in the control.
Notice!
At least one module
must be activated to permit operation of the device at the PROFIBUS
DP.
Notice!
Under some circumstances, not all 27 modules can be activated simultaneously in the con-
figuration tool. Otherwise, the available memory for a subscriber may be exceeded. The
maximum available memory for a device is control dependent.