Device parameters and interfaces
Leuze electronic
BPS 34
77
TNT 35/7-24V
8.1.7.21 Module 20: Velocity
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
Outputs the current velocity with the configured resolution and the desired scaling factor. In
order for the velocity to be calculated in the BPS 34 and output in this module, module 22
(Control velocity) must also be activated in the PROFIBUS project.
Parameter
none
Input data
Notice!
The scaling of the position value has no effect on the scaling or output of the velocity.
The direction of movement of the BPS 34 is displayed in module 23 "Velocity measurement
status" (see page 82) under
"Direction of movement".
Output data
none
Input data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Velocity
Current velocity
0
unsign
32
0 … 10’000’000
0
scaled
22
Input data length: 4 byte
a