Device parameters and interfaces
Leuze
electronic
62
BPS 34
Leuze electronic
Notice!
The events of the switch-on function and switch-off function are both linked to one another
with a logical OR.
Hex coding of module 8 "Switching output"
The value listed in the table shows the hex coding of the default settings.
Input data
none
Output data
Notice!
With the "PROFIBUS edge" function, the switching output can be directly activated or deac-
tivated by setting bit 0.0.
Switch-off
function
[OFF]
The parameter specifies the events
which reset the switching output:
- velocity valid
- velocity not valid
- position limit value 1 reached
- position limit value 1 not reached
- outside measurement range
- inside measurement range
- position limit value 2 reached
- position limit value 2 not reached
- erroneous measurement
- successful measurement
- PROFIBUS positive edge
- PROFIBUS negative edge
- velocity limit value reached
- velocity limit value not reached
6.0
6.1
6.2
6.3
6.4
6.5
6.6
6.7
7.2
7.3
7.4
7.5
7.6
7.7
Bits
for each
0: Not active
1: Active
0
0
0
0
0
0
0
0
0
1
0
0
0
0
–
22
22
14 + 16
14 + 16
10
10
15 + 17
15 + 17
1 + 9
1 + 9
8
8
25
25
Parameter length: 8 byte
e
Internal ad
dress
o
f modu
le 8
DC bias le
vel
ad
dress 0
V
e
locity limit v
a
lue
selection
ad
dress 1
Pulse duration
ad
dress 2
Switc
h
-on function
ad
dress 4
Switc
h
-off function
ad
dress 6
02
00
00
01 90
04 00
08 00
Output data
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Switching output
PROFIBUS edge
This bit can be used to operate
the switching output if the
"PROFIBUS edge" function is
configured.
0.0
Bit
0 -> 1: Positive edge
1 -> 0: Negative edge
0
–
–
Output data length: 1 byte
f