Leuze
electronic
Device parameters and interfaces
Leuze electronic
BPS 34
61
TNT 35/7-24V
8.1.7.8 Module 8: Switching output
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The module defines the mode of operation of the digital switching output.
Parameter
Parameter
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
DC bias
level
The parameter defines the DC bias
level of the switching output.
0
unsign
8
0: LOW (0 V)
1: HIGH (+U
B
)
0
–
–
Velocity
limit value
selection
Defines whether the switching out-
put is controlled by
static velocity limit value 1,
static velocity limit value 2,
static velocity limit value 3,
static velocity limit value 4
or the
dynamic velocity limit value
1.0
1.1
1.2
1.3
1.4
Bits
for each
0: No
1: Yes
0
0
0
0
0
–
25 for
static
26 for
dynamic
Pulse dura-
tion in [ms]
The parameter defines the switch-on
time period for the switching output. If
the value is 0, the signal is static.
2
unsign
16
0 … 1’300
400
ms
–
Switch-on
function
[ON]
The parameter defines the events
which set the switching output:
- velocity valid
- velocity not valid
- position limit value 1 reached
- position limit value 1 not reached
- outside measurement range
- inside measurement range
- position limit value 2 reached
- position limit value 2 not reached
- erroneous measurement
- successful measurement
- PROFIBUS positive edge
- PROFIBUS negative edge
- velocity limit value reached
- velocity limit value not reached
4.0
4.1
4.2
4.3
4.4
4.5
4.6
4.7
5.2
5.3
5.4
5.5
5.6
5.7
Bits
for each
0: Not active
1: Active
0
0
0
0
0
0
0
0
1
0
0
0
0
0
–
22
22
14 + 16
14 + 16
10
10
15 + 17
15 + 17
1 + 9
1 + 9
8
8
25
25
a
b
c
d