Device parameters and interfaces
Leuze electronic
BPS 34
59
TNT 35/7-24V
8.1.7.7 Module 7: Switching input
Notice!
Underlined in the CR column are the modules which must be activated in addition to the cur-
rent module.
Description
The module defines the mode of operation of the digital switching input.
Parameter
Parameter
Description
Rel.
addr.
Data
type
Value range
Default
Unit
CR to
module
Inversion
The parameter defines the logic
of the pending signal. In case of
an inversion, an external HIGH
level is interpreted as an internal
LOW level.
0
unsign
8
0: No (active high)
1: Yes (active low)
0
–
–
Mode
This parameter controls the
release of the switching input.
1
unsign
8
0: Off
1: On
1
–
–
Debounce
time in
[ms]
This parameter defines a
debounce time which is imple-
mented in software.
2
unsign
8
0 … 255
5
ms
–
Start-up
delay in
[ms]
The parameter influences the
timing during switch-on
3
unsign
16
0 … 65’535
0
ms
–
Pulse dura-
tion in [ms]
The parameter defines the mini-
mum pulse duration of the input
signal.
5
unsign
16
0 … 65’535
0
ms
–